User Instructions for GECO GH21TA controller
______________________________________________________________________________
Page 37 Edition I
19.06.2013
The following table specifies the assignment of outputs for connected devices, in safe mode
Safe mode – assignment of controller outputs
Device
connected
Type of output
Controller terminal
Feeder
Relay
9-10
Fan
Relay
12-13
Devices may only be connected to the GH21TA controller by a qualified
wiring technician
During safe mode it is not possible to regulate the speed of the fan
12.
Temperature limiter (STB).
Regulator The GH21TA controller is equipped with an independently operating, automatic
safety device called a temperature limiter (STB).
12.1.
How it works
If the water temperature reaches 95C, the temperature limiter automatically stops the flow of fuel
and air to the combustion chamber (the fuel feeder and fan are turned off). When the temperature
drops to around
20
0
C
it is possible to manually reconnect
12.2.
Reconnecting STB function
To restart the unit, press the ‘reset’ button, on the left hand side of the controller.