background image

The 

Quick Reference Card

 provides a quick overview of your spa's

main functions and the operations accessible with your digital control pad.

Quick Reference Card

Automatic water heater start:

When water temperature is 1˚F (0.5˚C) 

lower than the Set Point, the heater will 

automatically turn on until water tempera-

ture reaches Set Point plus 1˚F (0.5˚C).
 

The "Heater" icon lights up when

 

the heater is on. It flashes when

 

there is a request for more heat

 

but the heater has not yet started.

Real-time clock 

(K-4-10K):

Use 

Clock

 to set real-time clock. The display 

toggles every 5 seconds alternately showing 

the hourly time and the current water tem-

perature.

The system automatically performs two filter cycles per day, at 12-hour intervals. During a filter cycle, 

Pumps 2 & 3 and blower run at high speed for one minute, then Pump 1 runs at low speed for a 

programmed number of hours and the ozonator is activated.
To set filter cycle duration and frequency:

Troubleshooting

Programming filter cycles (K-4-10K)

Pumps have started up for

one minute on several oc-

casions and "Filter Cycle"

icon is flashing.

Not a bug but a feature!
Our

 Smart Winter 

Mode 

protects your spa

from the cold by automati-

cally turning pumps on for 

one minute several times a 

day to prevent water from 

freezing in pipes.

Water temperature is 

flashing.

Water temperature in the 

spa has reached 112˚F 

(44˚C).
Do not enter the water! 

Allow water to cool down.

The system will reset auto-

matically when water tem-

perature reaches 109˚F

(43˚C).
Call your dealer or service

supplier if problem persists.

3 flashing dots are dis-

played.

A problem has been 

detected.
Do not enter the water! 

Check and open water 

valves. Clean filter if neces-

sary. Check water level. 

Add water if necessary.
Shut power off and power 

your spa up again to reset 

the system.
Call your dealer or service 

supplier if problem persists.

The display is flashing.

A power failure has occurred.

Press any key to reset the

system.

Press 

Filter 

key. The

display will show 

Fdxx

,

with "xx" representing

the currently set filter

cycle duration in hours.

When the desired setting

is displayed, press 

Filter

again. The display will

show 

FFxx

, with "xx"

representing the filter

cycle frequency per day.

Use 

Up

 or 

Down

 arrow

key to change setting.
  0 = no filtration

12 = continuous

filtration

Use 

Up

 or 

Down

 arrow

key to change setting 

(from 1 to 4, depending

on selected duration).

When the desired set-

ting is displayed, press

Filter 

to confirm. The 

"Filter Cycle" icon lights

up when a filter cycle

is on.

Dual-Pump & Blower System With K-4-8K

Three-Pump & Blower System With K-4-10K

Setting water temperature:

Use 

Up

 or 

Down

 arrow key to increase or 

decrease water temperature. The tempera-

ture setting will be displayed for 5 seconds

to confirm your new selection.
 

The "Set Point" symbol indicates

 

the desired temperature, NOT

 

the current water temperature!

Water temperature can be adjusted by 1˚ in-

crements from 59 to 104˚F (15 to 40˚C).

Starting Pump 1:

Press 

Pump 1

 to turn pump on at low speed 

(for dual-speed pump). Pressing a second 

time turns pump to high speed. A third time 

turns pump off. A built-in timer automatically 

turns pump off after a predetermined period 

of time, unless manually deactivated first.
 

The "Pump 1" icon lights up when

 

pump is on at high speed. It flashes

 

when pump is on at low speed.

1

Starting Pump 2:

Press 

Pump 2

 to turn pump on at low speed 

(for dual-speed pump). Pressing a second 

time turns pump to high speed. A third time 

turns pump off. A built-in timer automatically 

turns pump off after a predetermined period 

of time, unless manually deactivated first.
 

The "Pump 2" icon lights up when

 

pump is on at high speed. It flashes

 

when pump is on at low speed.

2

Starting Pump 3 (K-4-10K):

Press 

Pump 3

 to turn pump on. Press a 

second time to turn pump off. A built-in 

timer automatically turns pump off after a 

predetermined period of time, unless it has 

been manually deactivated.
 

The "Pump 2" icon lights up when

 

pump is on.

2

Turning the light on:

Press 

Light

 to turn light on at high intensity. 

Press a second time to turn light to medium 

intensity and a third time to turn light to low 

intensity. A fourth time turns light off. A built-in 

timer automatically turns light off after 2 hours, 

unless it has been manually deactivated.
 

The "Light" icon lights up when light

 

is on at high intensity. It flashes when

 

light is on at medium or low intensity.

Fiber Box Option:

 If your spa is equipped with 

an optional fiber box, press 

Light

 key to turn 

fiber box (motor & light) on. Press a second 

time to turn fiber box motor off and leave light 

on. A third time turns both motor and light off. 

The "Light" icon is displayed when fiber box 

light is on. It flashes when motor and light are 

on at the same time. A built-in timer automati-

cally turns fiber box off after 2 hours, unless 

manually deactivated first.

Starting the blower:

Press 

Blower

 to turn blower on at high 

speed. Press a second time to turn blower 

to low speed. Pressing a third time turns 

blower off. A built-in timer automatically 

turns blower off after a predetermined 

period of time, unless it has been manually 

deactivated.
 

The "Blower" icon lights up when

 

blower is on at high speed. It flashes

 

when blower is on at low speed.

MC-MP SPA PACK