Gecko INK 500 Скачать руководство пользователя страница 22

in.k500 TechBook

21

5

Code

Message

hl

Warning! hl Error

FlO

no flow for more than 2 hours

FlO

no flow condition

hR

Danger! Relay stuck

Oh

Warning! Spa temp high

Pr

Warning! temp probes defective

AOh

Internal pack temp high

FlC

Flow switch closed

SP in

Input voltage issue

Rh nC

Comm error  inxm2 - intherm

Rh ID

inxm2 - intherm incompatible

SC ER

learning mode error

F1

inxm2 Fuse # 1 is blown

F2

inxm2 Fuse # 2 is blown

F3

inxm2 Fuse # 3 is blown

hr

Danger! thermal fuse error

uPl

the spa pack does not have valid software Please insert valid instick to reprogram spa pack

the list below shows the different error messages that can appear on the home screen 
Refer to the troubleshooting and error codes section of the techBook for your spa pack system

Error messages

Содержание INK 500

Страница 1: ...in k500 TM intuitive color keypad Full color control Compact Versatile TechBook ...

Страница 2: ... stream 9 in tune 9 Keypad functions 10 Power 10 Main screen 10 Start or stop accessories 10 Water temperature 11 Settings 11 Water care 12 Water care modes 12 Modifying schedules 13 Audio 13 Maintenance version 7 00 and higher 14 Maintenance reminders version 7 00 and higher 14 Standby version 6 00 and higher 14 Date and time 15 Keypad settings 15 WiFi version 7 00 and higher 16 Config 17 Restore...

Страница 3: ... HAZARDOUS CONDITION A condition that is potentially damaging and or dangerous to the operator or surroundings This includes but is not limited to fire flooding or other water damage dielectric breakdowns presence of high voltage etc MAINTENANCE If you have problems do not attempt to repair the unit yourself Return it to your dealer or service station for servicing ACCESSORY PARTS Be sure to use o...

Страница 4: ...n in k500 intuitive color keypad The in k500 is built with all the great features you ve come to love in the in k800 but in a smaller package It is discreet compact and unobtrusively beautiful Save space without losing out on function ...

Страница 5: ...00 keypad layout Functions for keys 1 and 2 will depend on your system s low level configuration Settings Light Key Mode Up Key 1 Down Selection lights Key 2 Overview 7 16 181 74 mm 3 33 84 46 mm 1 95 49 51 mm in k500 dimensions ...

Страница 6: ...k the template on chosen location Cut out an opening according to the template Clean the installation surface and peel the adhesive gasket from the back of the keypad Insert keypad and align it correctly then ensure it is properly glued by gently pressing evenly on the entire surface Installation Gasket with or without adhesive Optional wing nuts and spacers ...

Страница 7: ...6 in k500 TechBook 5 Drilling template Installation 2 625 66 68mm R0 900 22 86mm 6 750 171 45mm 6 250 158 75mm R0 250 6 35mm ...

Страница 8: ... back of the in k500 should not be enclosed where water can gather but instead cut out Connecting in k500 keypad to the spa pack Installation notes To connect the in k500 keypad simply insert its in link connector into the appropriate keypad connector of the pack enclosure as illustrated Main keypad in k500 Vent hole on back of keypad should not be blocked ...

Страница 9: ...n the message or contact your dealer for more information Power up message The in k500 keypad does not store the date time When the in k500 starts up after a power loss a message will prompt the user to reprogram the date and time Installation Note With the in k500 equipped with a real time clock RTC If the power was lost for few hours this message will not appear ...

Страница 10: ...ct the in stream to the CO port of the spa pack in tune Use the adapter cable Part 9920 400976 to connect the in tune to the CO port of the spa pack See Factory reset Audio configuration section for details on setting up audio Connecting the in stream and in tune to the spa pack ...

Страница 11: ...speed or state of the devices running on your spa When an accessory has more than two states press the button until it reaches the desired state Main screen The main screen gives you access to your accessories and water temperature At the bottom of the screen you will see any error or maintenance messages that are present Power Press any button to turn the keypad on After 30 minutes without activi...

Страница 12: ...n the current temperature Heating to xx x will be indicated Normally there is a short delay before the heating starts during which Heating Suspended is indicated Settings From the home page you can access the Settings where you will find Water care Audio if installed Standby version 6 00 only Maintenance version 7 00 and higher Date time Keypad Wi Fi Version 7 00 and higher Only available on in to...

Страница 13: ...w the spa s set temperature Default pack value Water care modes Away In this mode the spa will always be in economy the set point will be reduced by 20 F Beginner The spa will never be in economy mode and will be filtering according to the pack s low level configuration Energy Savings The spa will be in economy mode during the peak hours of the day and resume normal mode on the weekend Super Energ...

Страница 14: ...elected Water Care menu Use the arrow keys to choose a schedule to modify choice of economy and filtration schedules Use the Light key to move between parameters You have several possibilities for the schedule Mon Fri weekend every day or single days The schedules will be repeated every week The time and duration are set in 30 minute increments Once you have set the schedule use Key 1 to go back E...

Страница 15: ...time left before maintenance is required as well as to reset the time once a task is completed Use theUp and Down keys to move through the list To reset a task select it by pressing Light key then confirm when prompted Once you have confirmed the task will be reset Standby version 6 00 and higher The Standby mode allows you to service your spa Pumps will stop for 30 minutes and automatically resta...

Страница 16: ... main spa menu Note With the in k500 equipped with a selectable rim light color modul If the RGB backlight option is enabled in the spa configuration an option will appear to allow selection of the keypad rim light color Date and time Here you can adjust the time format change the year date and time Use the arrows to choose the setting that you want to adjust and select it by pressing the Light ke...

Страница 17: ...ist Select your network by pressing on Light key If the WiFi network is password protected enter it when prompted Use the arrow keys to choose your letters and change the type of character uppercase lowercase number symbol Use Key 2 to move the curser forward Use Key 1 to backspace Use Light key to confim If no password is required the in touch will connect automatically Once the in touch module i...

Страница 18: ...parameters and the Light key to select a parameter to change Please refer to the TechBook for your specific spa pack for details about the low level settings Once you have reached Number of Phases in the menu you cannot use the arrow keys to go back up to Low level Configuration Please go back and re enter the Config menu The table below shows the key assignation based on the accessories selected ...

Страница 19: ...store Audio configuration When you select Restore you will be asked to confirm your choice Doing so will reset all settings to factory default Following a restore you will be asked to choose your audio source Use the arrow key to choose between in stream in tune and no other audio This should only be done at installation or when replacing a part Keypad functions ...

Страница 20: ...e Down key to increase or decrease the volume Turn power On Off version 7 00 and higher Press and hold the Play Pause key for 3 seconds to turn the in tune on or off Changing tracks Use the Last Track and Next Track keys to change tracks for the CD or AUX input When in Radio mode the Last Track and Next Track keys will move through preset radio stations on the selected band To change bands or pres...

Страница 21: ...djusting the volume Press the Up or the Down key to increase or decrease the volume Turn power On Off version 7 00 and higher Press and hold the Play Pause key for 3 seconds to turn the in stream on or off Changing tracks Use the Last Track and Next Track keys to change tracks Disconnect or Unpair Bluetooth These options can be found under the Audio section in the Settings menu Next track Last tra...

Страница 22: ...error in xm2 in therm RH ID in xm2 in therm incompatible SC ER Learning mode error F1 in xm2 Fuse 1 is blown F2 in xm2 Fuse 2 is blown F3 in xm2 Fuse 3 is blown Hr Danger Thermal fuse error UPL The spa pack does not have valid software Please insert valid in stick to reprogram spa pack The list below shows the different error messages that can appear on the home screen Refer to the troubleshooting...

Страница 23: ...perating temperature 4 F 20 C to149 F 65 C Storage temperature 22 F 30 C to185 F 85 C Humidity Up to 70 condensing Water ingress protection IPX 5 Mechanical Weight 0 78 lb 0 35kg Dimensions W x H x D 7 155 x 3 325 x 1 949 182 mm x 84 mm x 50 mm Compatibility in yt in ye in yj in xe or in xm2 spa packs with appropriate software revision Specifications ...

Страница 24: ...ons Quebec City Qc G2E 5W6 Canada 1 800 78 GECKO www geckoalliance com 9919 101209 C Rev 01 2015 Groupe Gecko Alliance Inc 2015 All trademarks or registered trademarks are the property of their respective owners Printed in Canada ...