Quick Start Card
in.yj-2-V3
™
North American version
2- Connect the main power
1- Connect all outputs & keypads
3- Select spa configuration (see back page)
3
At first startup the keypad display
will show
L 1
or
LL 1
.
Note: To re-enter the Low level
selection menu, hold the
Pump 1 key for 30 seconds.
Note
: If the keypad does not have a
Program
or
Filter
key, use the
Light
key instead.
Note:
For the
Color keypad series
,
select
Settings menu
, go into
Electrical config
and choose the
appropriate Low level.
Use the
Up/Down
key to choose the
new Low level configuration number.
Press the
Program
key to confirm the
selection.
2
1
Heater connections
(P3 & P4 Element, P5 Ground)
P33 - Light outputs (12 V DC, 1 AMP)
P38 - in.lu.me
Main power entry connection
Aperture Ø 2.54 cm (1'')
Ground:
connect all Green wires: P27, P28, P29 or P30
C1 - Main keypad connector
P1 - Heater communication cable
Bonding lugs:
connect redundant ground cable
to heater, pumps, etc.
68,1 L/min (18 GPM) minimum water flow required.
This side up
Outputs:
in.yj-2 pack has 2 relay controlled outputs
Out 1: K7-P
Out 2: K6-P
Direct: P25
240 V (4 wires)
Remove and discard brown wire and
insert each wire into the appropriate
socket of the main terminal block ac-
cording to the color code indicated on
the sticker. Use a flat screwdriver to
tighten the screws on the terminal.
Look at the pump and accessory voltage requirement and make sure to connect
each WHITE common wire to the correct tab on the board: Use any neutral tab for
120 V or use any LINE2 tab for 240 V
WARNING!
All connections must be made by a qualified electrician in
accordance with the national electrical code and any state, provincial or local
electrical code in effect at the time of the installation. This product must always be
connected to circuit protected by a Ground Fault Circuit Interrupter (GFCI).
2.a- Electrical wiring
2.b- Pump & accessory voltage
Press and hold the
Program
key for
20 seconds until you access the
breaker setting menu.
Note:
For the
Color keypad series
,
select
Settings menu
, go into
Electri-
cal config
and choose Input current.
4- Select breaker current
Breaker setting for GFCI used.
GFCI
b
50 A
40 A
40 A
32 A
30 A
24 A
20 A
16 A
15 A
12 A
Use the
Up/Down
key to select the
desired value. Then press the
Program
key to confirm the selection.
Note
: If the keypad does not have the
Program
or
Filter
key, use the
Light
key
instead.
The values displayed by the system
correspond to
80%
of the maximum
amperage capacity of the GFCI.
98
For more information, see our
website: www.geckoalliance.com
For more information, see our
website: www.geckoalliance.com
3
2
1
(10 to 20A is only to be use with
120V input)
Neutral: connect White wires from
120V pump / acc : P18, P19, P20, P21 or P35
Line 2: connect White wires from 240V
pump / acc : P14, P15, P16 or P37
120 V (3 wires)
DO NOT REMOVE THE BROWN WIRE.
Insert each wire into the appropriate
socket of the main terminal block
according to the color code indicated
on the sticker. Use a flat screwdriver to
tighten the screws on the terminal.
CO - Communication links
in.touch, in.stik, Aux keypad in.k120