Quick Start Card

in.yj-2-V3

 

North American version

2- Connect the main power

1- Connect all outputs & keypads

3- Select spa configuration (see back page)

3

At first startup the keypad display

will show 

L 1 

or

 LL 1

.

Note: To re-enter the Low level 

selection menu, hold the 

Pump 1 key for 30 seconds.

Note

: If the keypad does not have a 

Program

 or 

Filter

 key, use the 

Light

 

key  instead.

Note: 

For the 

Color keypad series

select 

Settings menu

, go into 

Electrical config

 and choose the 

appropriate Low level.

Use the 

Up/Down 

key to choose the 

new Low level configuration number.

Press the 

Program 

key to confirm the 

selection.

2

1

Heater connections 
(P3 & P4 Element, P5 Ground)

P33 - Light outputs (12 V DC, 1 AMP)
P38 - in.lu.me

Main power entry connection
Aperture Ø 2.54 cm (1'')

Ground: 
connect all Green wires: P27, P28, P29 or P30

C1 - Main keypad connector

P1 - Heater communication cable

Bonding lugs:
connect redundant ground cable 
to heater, pumps, etc.

68,1 L/min (18 GPM) minimum water flow required.

This side up

Outputs:
in.yj-2 pack has 2 relay controlled outputs
Out 1: K7-P
Out 2: K6-P
Direct: P25

240 V (4 wires)

Remove and discard brown wire and 

insert each wire into the appropriate 

socket of the main terminal block ac-

cording to the color code indicated on 

the sticker. Use a flat screwdriver to 

tighten the screws on the terminal.

Look at the pump and accessory voltage requirement and make sure to connect 

each WHITE common wire to the correct tab on the board: Use any neutral tab for 

120 V or use any LINE2 tab for 240 V

WARNING! 

All connections must be made by a qualified electrician in 

accordance with the national electrical code and any state, provincial or local 

electrical code in effect at the time of the installation. This product must always be 

connected to circuit protected by a Ground Fault Circuit Interrupter (GFCI).

2.a- Electrical wiring

2.b- Pump & accessory voltage

Press and hold the

 Program 

key for 

20 seconds until you access the 

breaker setting menu.

Note:

 For the 

Color keypad series

select 

Settings menu

, go into 

Electri-

cal config

 and choose Input current.

4- Select breaker current

Breaker setting for GFCI used.

GFCI

b

50 A

40 A

40 A

32 A

30 A

24 A

20 A

16 A

15 A

12 A

Use the 

Up/Down

 key to select the 

desired value. Then press the 

Program 

key to confirm the selection.

Note

: If the keypad does not have the 

Program

 or 

Filter

 key, use the 

Light

 key 

instead.

The values displayed by the system 

correspond to

 80%

 of the maximum 

amperage capacity of the GFCI.

98

For more information, see our 

website: www.geckoalliance.com

For more information, see our 

website: www.geckoalliance.com

3

2

1

(10 to 20A is only to be use with 

120V input)

Neutral: connect White wires from 
120V pump / acc : P18, P19, P20, P21 or P35

Line 2: connect White wires from 240V 
pump / acc : P14, P15, P16 or P37

120 V (3 wires)

DO NOT REMOVE THE BROWN WIRE.

Insert each wire into the appropriate 

socket of the main terminal block 

according to the color code indicated 

on the sticker. Use a flat screwdriver to 

tighten the screws on the terminal.

CO - Communication links 
in.touch, in.stik, Aux keypad in.k120