background image

____________

GENESIS AG550S 

 

© 2007 

GECKO INSTRUMENTS. 

All Rights Reserved. 

Website: www.geckoinstruments.com Email: [email protected] 

 

           

This is the ground lift switch. 

 

           

Serial number of your GENESIS

 

is located here. 

 
 

3. APPLICATIONS 

The GENESIS

 

is designed to take on various applications.  

 

3.1 Dual channel, parallel and mono bridged operating modes. 

Dual channel mode is the most common operating mode of amplifiers. Both 
channels operate fully independently from one another. In this operating mode, 
two independent speakers are connected at the outputs. The input signal of each 
channel will be driven to the output of respective channel. To activate this mode, 
select switch            to 

STEREO

.  

 
Running in parallel mode enables you to feed a signal via one of the inputs into 
both outputs. Each channel drives its own loudspeaker with independent 
amplification, filter and limit characteristics. To link the inputs, set switch            to 

PARALLEL

.  

 
Mono-bridged operating mode enables you to add up the respective voltage of 
both channels and use it to drive a single loudspeaker. The voltage is therefore 
doubled, the peak power is quadrupled, and the program power is approximately 
three times as high as that of the individual channels. The input, output, gain, 
filter and limiter controls belonging to 

CH.A

 are used when running in mono-

bridged mode. The controls belonging to 

CH.B

 are not used.  To prevent signal 

cancellation due to internal phase inversion, the gain control of 

CH.B

 must be 

turned to its leftmost position. 
 
 
Use this operating mode to route the power from both channels to a single 8 

 or 

 load.  To do so, set switch            to 

BRIDGED

 position. To use the binding 

posts as your output, you 

MUST

 use the two middle posts only. 

 
Please note that the mono-bridged mode puts added demands on amplifiers and 
speakers. Excessive distortion may occasionally completely mute the amplifier’s 
outputs as well as cause permanent damage to the speakers. Please assure that 
your speakers (minimum impedance 4 

) as well as the cables used can handle 

the extra power generated in this mode. 
  
 
 
 
 
 

14 

15 

8

8

Содержание GENESIS AG550S

Страница 1: ...User s Manual Version 1 1 0 January 2007 www geckoinstruments com GENESIS TO MUSICAL INSPIRATIONS...

Страница 2: ...t attempt to clean this unit with chemical solvents as this may damage the finish Clean only with dry cloth Do not block any ventilation openings Do not install near any heat sources such as radiators...

Страница 3: ...eed heat sensing fan and an oversize heatsink tunnel for efficient heat dissipation Precise signal clip power and protection LED indicators to monitor performance Professional SPEAKON and banana bindi...

Страница 4: ...usic world and recording industry We believe in giving the best of quality and features at the best affordable price It s been our philosophy all this while that good sound can be achieved without hav...

Страница 5: ...nstruments com 5 TABLE OF CONTENTS 1 INTRODUCTION 6 1 1 Before you get started 6 1 1 1 Shipment 6 1 1 2 Initial operation 6 1 1 3 Online registration 6 2 CONTROL ELEMENTS 7 2 1 Front panel 8 2 2 Rear...

Страница 6: ...unit is provided with sufficient ventilation and never placed your GENESIS amplifier on top of any heat emanating equipment or in the vicinity of a heater to avoid the risk of overheating The mains c...

Страница 7: ...unit off does not mean that it is fully disconnected from the mains When not using the unit for prolonged periods of time please unplug the unit s power cord from the power outlet These ventilation op...

Страница 8: ...evel to ensure trouble free operation These are the SPEAKON compatible outputs CH A and CH B When running the unit in mono bridged mode use CH A output exclusively These are the banana plugs acceptabl...

Страница 9: ...idged operating mode enables you to add up the respective voltage of both channels and use it to drive a single loudspeaker The voltage is therefore doubled the peak power is quadrupled and the progra...

Страница 10: ...nse 20 Hz 25 kHz 0 1 0 3 dB Distortion 0 02 4 20 Hz 25 kHz Input Sensitivity 4 dB for Rated Output Controls Front POWER Switch Gain Control CH A CH B Rear GROUND LIFT Switch MODE Switch Output Offset...

Страница 11: ...t needs to be modified or adapted in order to comply with applicable technical or safety standards on a national or local level in any country which is not the country where the product was originally...

Страница 12: ...KO INSTRUMENTS will return the unit C O D with a separate invoice for freight and packing Such costs will also be invoiced separately when the buyer has sent in a written repair order 9 This warranty...

Отзывы: