Assembling the electric pack and
the housing
1
Attach the upper part of the housing to
close the electric pack. Make sure the seal is
correctly positioned.
2
Add the housing clips to fix the housing
(seven big and two small clips).
3
Connect the fan cable connector inside the
electric pack. Make sure the cable passes
the provided recess in the electric pack
entry seal.
Fix the fan cable with tape to the electric
pack.
4
Attach the right and the left protective
bumper to the electric pack. Make sure all
housing clips are positioned correctly.