User manual Geberit AquaClean 4000
14
Troubleshooting
Malfunctions during operation
DANGER
Danger of fatal electric shock
`
Never open and repair the device yourself
`
Never replace damaged mains connection cables yourself
`
Contact customer service
Malfunction
Malfunction
Malfunction
Malfunction
Cause
Cause
Cause
Cause
Fault clearance
Fault clearance
Fault clearance
Fault clearance
No function
Mains plug is not connected to
power outlet
Connect the mains plug
Defective fuse on electrical
distributor
Replace the fuse on the electrical
distributor
Fuse in mains connection cable
is defective
Disconnect the mains plug and
contact customer service
Power supply is interrupted
Have the power supply checked
by a skilled person
Shower water temperature is
too low
Heating element is not switched
on
Set the <water heater function>
to ON on the control panel
Warm-up time too short when
heating element is in economy
mode
Set the <water heater function>
to ON on the control panel
Shower spray is too weak or
no water is spraying out at all
Spray intensity is set too low
Increase the spray intensity
Spray nozzle clogged or blocked
with limescale
Clean or replace the spray nozzle
Basket filter is clogged or
blocked with limescale
Clean or replace the basket filter
Spray arm does not retract
Power supply is interrupted
Restore the power supply. The
spray arm will retract
automatically
Enhancement solution is
defective
Switch off the enhancement
solution and contact customer
service
Lowering function not
working
Hydraulics are defective
Contact customer service
Water runs out of the
overflow on the left next to
the spray arm
Disconnect the mains plug, close
the angle stop valve, and contact
customer service