Setting the flush time and flush interval
The flush time and flush interval must be set before the urinal is installed. If the settings need
to be changed later on, the urinal will need to be removed and then reinstalled again by
following the manufacturer’s instructions.
Factory setting:
• flush time: 5.5 seconds (approx. 1.5 l at 4 bar)
• flush interval: 2 hours
Setting the flush time and flush interval:
1
Press the <Flush time> button for 1 second.
✓ The flush time setting advances one level. The current setting is shown with flash
pulses as indicated in the table below.
2
Press the <Flush time> button repeatedly for 1 second until the required flush time is
set.
Level
Red LED
Flush interval [h]
Flush time [s]
Approximate flush
volume at 3–4 bar [l]
1
1 flash pulse
2
5.5
1.5
2
2 flash pulses
4
3
3 flash pulses
8
9.5
2.5
4
4 flash pulses
12
5
5 flash pulses
18
11.5
3
6
6 flash pulses
24
Each cycle of setting options ends once the button has been pressed 6 times. The
next time the button is pressed, the setting options start from the beginning again.
Putting into operation
While the urinal ceramic appliance is being installed, the brightness sensor in the control unit
is covered, which activates the urinal flush control. 3 minutes after the sensor is covered, the
function is confirmed as indicated in the table below.
Flush actuation
Function
3x flush for 2 seconds, 8-second pause and
1x flush for 2 seconds
Urinal flush control is functional.
16
9007203488149771-1 © 07-2019
968.958.00.0(01)
Содержание 1000-1 N
Страница 1: ...OPERATION MANUAL BETRIEBSANLEITUNG MANUEL D UTILISATION ISTRUZIONI DI FUNZIONAMENTO...
Страница 43: ...1 1 2 3 4 9007203488149771 1 07 2019 968 958 00 0 01 43...
Страница 44: ...2 1 2 NN 3 4 NN 5 44 9007203488149771 1 07 2019 968 958 00 0 01...
Страница 45: ...9007203488149771 1 07 2019 968 958 00 0 01 45...
Страница 46: ...46 9007203488149771 1 07 2019 968 958 00 0 01...
Страница 47: ...9007203488149771 1 07 2019 968 958 00 0 01 47...