EN
Technical data
Type 1000-1 N
Type 1000-1
Nominal voltage
230 V AC
–
Mains frequency
50–60 Hz
–
Mains connection
Two-wire mains cable
–
Battery type
–
CR-P2 (6 V)
Service life of battery supplied
–
~ 5 years
Protection degree
IP54
IP54
Operating temperature
4–30 °C
4–30 °C
Power consumption
1.3 W
1.3 W
Flow pressure
1–10 bar
1–10 bar
100–1000 kPa
100–1000 kPa
Flush time, factory setting
5.5 s (1.5 l at 4 bar)
5.5 s (1.5 l at 4 bar)
Interval flush, factory setting
2 h
2 h
Interval flush, adjustment range
2 / 4 / 8 / 12 / 18 / 24 h
2 / 4 / 8 / 12 / 18 / 24 h
Operating mode
The urinal flush control actuates a flush at a set flush interval. There is no user recognition
function.
When the factory setting applies, the urinal flush control actuates a flush with a flush time of
5.5 seconds (approximately 1.5 l at 4 bar) every 2 hours. The flush time and flush interval can
be set in 6 levels. → See "Setting the flush time and flush interval", page 16.