Assembly versions - potential free contacts
Cody Light HF 1 / 1 = X6
Cody Light HF 1 / 2 = X6 + X7
This product complies with:
EC Electromagnetic Compatibility Directives
EN 61000-6-1 08/2002
EN 61000-6-3 08/2002
Low Voltage Directive 2006/42/EC
Technical data
Supply voltage: 20-28V AC/DC, 230-240 V AC
Output: 250V AC 5A
Connections: 1.5 mm² max.
Ambient temperature: -20 °C to +60 °C
RC transmitter
Put DIP 4 to ON
Press the desired
button on the remote
control
LED flashes
1x long
Put DIP of the
relay used
(1 or 2 ) to ON
Put all DIP to OFF
The transmitter is programmed to the desired relay!
Teach-in of remote controls
Make sure before the teach-in that the optional wireless module is plugged in firmly at the logic board.
230/240VAC