TIPTOMATIC:

Especially for garage doors the Cody Light HF is designed with 
TIPTOMATIC timing. After entering a pass code and within a period of 
60 seconds (adjustable) this function allows you to control the door 
with any key, except for the         button, and without the need to enter 
the pass code once again. This function, however, can be interrupted 
prior to the expiration of the 60 seconds, by pressing the         button.

Lock-out function:

If the lock-out function is activated, the Cody Light HF automatically 
blocks any input for a set period after the input of a wrong pass code 
which is signalled with a (3 beeps) sound signal.
The end of the blocking time is signalled by a long sound signal.

General reset

General reset

Put DIP switch 4 to 

ON 

Push reset button 

on the PCB 

> 5 sec.

Put DIP switch 

back to OFF

All factory settings are restored by the general reset !

Factory settings (default settings):

 all memory slots erased (except 00)

 Tiptomatic time = 60 sec.

 switching time = 1 sec.

 lock-out time = 20 sec.

Содержание Cody Light HF 1/1

Страница 1: ...V1 0 Cody Light HF 1 1 1 2 GB Assembly connection and maintenance of the device may only be executed by personnel trained accordingly At this the underlying national and local regulations have to be observed ...

Страница 2: ...er programming the pass code For opening or closing of the door only a four or five digit numeral code pass code has to be entered After correct input of the pass code and pushing the button the drive is triggered by the potential free relay contact Pass code The pass code is either a four or five digit numeral code by which you operate your door drive unit You have the possibility to store up to ...

Страница 3: ...essing the button Lock out function If the lock out function is activated the Cody Light HF automatically blocks any input for a set period after the input of a wrong pass code which is signalled with a 3 beeps sound signal The end of the blocking time is signalled by a long sound signal General reset General reset Put DIP switch 4 to ON Push reset button on the PCB 5 sec Put DIP switch back to OF...

Страница 4: ... otherwise the water protection of the appliance cannot be assured 6 According to connection diagram connect the wires to the corresponding terminals geba GmbH is released of its obligations regarding guarantee and product liability if without prior permission the unit has been modified or if the installation is unproper or not in accordance with our instruction manual The installer has to take ca...

Страница 5: ...voltage 20 28V AC DC 230 240 V AC Output 250V AC 5A Connections 1 5 mm max Ambient temperature 20 C to 60 C RC transmitter Put DIP 4 to ON Press the desired button on the remote control LED flashes 1x long Put DIP of the relay used 1 or 2 to ON Put all DIP to OFF The transmitter is programmed to the desired relay Teach in of remote controls Make sure before the teach in that the optional wireless ...

Страница 6: ...ypad Enter 4 or 5 digit pass code sound signal 1x long push button Set all DIP to OFF The new pass code is now saved The selected memory slot of the pass code is now deleted sound signal 1x long push button push button Set all DIP to OFF sound signal 1x long Enter 4 or 5 digit pass code push button Entering a pass code A correct code is detected the corresponding relay is switched Before the actua...

Отзывы: