STEP 1 (continued)

7.

 Remove and save the screws (2) securing 

extension bracket to the extension duct. Remove 
and save the screws (2) securing the lateral duct 
adapter to the case mounting plate at the extension 
end. Remove and save the screws (2) securing 
the duct adapter to the case mounting plate on 
opposite end.

8.

 Carefully lift extension duct until the two shoulder 

screws disengage from the flange of the duct 
adapter. Then slide the duct adapter forward until it 
clears the unit.

9.

 Remove and retain end cap and screws by 

removing the screws (4) securing the end cap to 
the existing duct adapter. 

10. 

Remove and retain the grille and screws by 

removing the 4 screws securing the grille to the 
existing duct adapter.

11. 

Remove and discard black dampener under grill.

12. 

Remove and retain the two shoulder bolt and two 

nuts from existing duct adapter.

STEP 2 
Install the new lateral duct adapter

1.

 Prepare duct adapter for installation by Installing 

the end cap on the correct end for your application.  
This will be the opposite end where the extension 
duct will be installed. Secure with four screws 
removed in step 1. 

2.

 Install new damper under grille on top of lateral 

duct adapter for 70% air discharge into primary 
room (room which the unit is installed) and 30% 
discharge into secondary (adjacent) room. By not 
installing the new damper, air distribution  will be 
80% Primary room and 20% secondary room. To 
install the new damper,  place damper centered in 
the exist grille such that the flange on damper lays 
inside the grille flange. Place grille over the hole 
in the duct adapter, ensuring the damper does not 
fall out of place and secure with the four screws 
removed in step 1.

3.

 Install the two shoulder screws and nuts  (removed 

in Step 1) on the end where the existing extension 
duct is to be mounted, ensuring the nuts are placed 
inside of the adapter duct flange and shoulder 
screw extend to the outside of the flange.  

Flange

Duct 

extension

Lateral duct dapter

Shoulder screws

Thumb

screw

s

Discharge grille 

and damper

Lateral duct adapter

Transition duc

t

Extension Bracket

Extension Mounting 

Bracket Screws

Case Mounting 

Screws

2

Содержание RAK7013

Страница 1: ...bes how to modify an existing duct installation to be used with the new rounded room cabinet front AZ45 and AZ65 series No changes are required on the existing lateral duct extension when this RAK7013 is used There are a number of parts on the existing lateral duct adapter that will be required to complete the RAK7013 installation Save all parts until the installation is complete It is important t...

Страница 2: ...he correct end for your application This will be the opposite end where the extension duct will be installed Secure with four screws removed in step 1 2 Install new damper under grille on top of lateral duct adapter for 70 air discharge into primary room room which the unit is installed and 30 discharge into secondary adjacent room By not installing the new damper air distribution will be 80 Prima...

Страница 3: ...On the new lateral duct adapter remove the two thumb screws securing the transition duct to the lateral duct adapter Carefully slide the transition duct forward and off of the lateral duct adapter 2 Install the new RAK7013 by reversing the removal items in Step 1 items 7 and 6 Thumb screws Discharge grille and damper Lateral duct adapter Transition duct End cap STEP 4 Chassis modification and inst...

Страница 4: ...ward to remove it from the chassis 3 Remove the room cabinet front 4 Remove the chassis from the case for service Transition duct STEP 4 continued 6 Reinstall the room cabinet front by hooking the top over the rail along the chassis top Push it in at the bottom 7 Remove the air filters from room cabinet front 8 Slide the transition duct into place under the adapter and secure it with the two thumb...

Отзывы: