Tools Needed

 Blade-type 

screwdriver 

 Phillips 

head 

screwdriver

  1/4” and 5/16” Nut drivers

STEP 1 
Removal of the adapter from the 
case and lateral duct extension

1.

 Disconnect the power to the unit.

2.

 Remove the three screws securing the transition 

duct to the bottom of the lateral duct adapter.

3.

 Carefully slide the transition duct forward and 

remove.

4.

 Remove the room cabinet front from the unit.

5.

 Remove the chassis-to-case screws (two on each 

end) and carefully slide the chassis from the case.

6.

 Place a support under the existing duct  

extension to prevent the duct extension from 
sagging downward when the primary duct is 
disconnected and removed.

Parts Included

  Lateral duct adapter 

  Transition duct assembly

  Metal seal strip

 Clips 

(2)

  Thumb screws (2)

Important Notes

  This instruction describes how to modify an existing 

duct installation to be used with the  
new rounded room cabinet front (AZ45 and AZ65 
series). No changes are required on the existing 
lateral duct extension when this RAK7013 is used.

  There are a number of parts on the existing lateral 

duct adapter that will be required to complete 
the RAK7013 installation. Save all parts until the 
installation is complete. It is important that these 
parts not be discarded.

Lateral duct adapter

Duct 

extension

Case

Support

End 
cap

Transition duct

Lateral duct adapter

6

1

»

2

8

3

»

8

Installation Instructions

for your new

Before you begin - Read these instructions completely and carefully.
IMPORTANT – OBSERVE ALL GOVERNING CODES AND ORDINANCES. 
Note to Installer – Be sure to leave these instructions with the Consumer. 
Note to Consumer – Keep these instructions with your Owner’s Manual for future reference.

RAK7013

Duct adapter

Pub No. 31-30813      07-16 GEA

GE is a trademark of the General Electric Company. Manufactured under trademark license.

Содержание RAK7013

Страница 1: ...bes how to modify an existing duct installation to be used with the new rounded room cabinet front AZ45 and AZ65 series No changes are required on the existing lateral duct extension when this RAK7013 is used There are a number of parts on the existing lateral duct adapter that will be required to complete the RAK7013 installation Save all parts until the installation is complete It is important t...

Страница 2: ...he correct end for your application This will be the opposite end where the extension duct will be installed Secure with four screws removed in step 1 2 Install new damper under grille on top of lateral duct adapter for 70 air discharge into primary room room which the unit is installed and 30 discharge into secondary adjacent room By not installing the new damper air distribution will be 80 Prima...

Страница 3: ...On the new lateral duct adapter remove the two thumb screws securing the transition duct to the lateral duct adapter Carefully slide the transition duct forward and off of the lateral duct adapter 2 Install the new RAK7013 by reversing the removal items in Step 1 items 7 and 6 Thumb screws Discharge grille and damper Lateral duct adapter Transition duct End cap STEP 4 Chassis modification and inst...

Страница 4: ...ward to remove it from the chassis 3 Remove the room cabinet front 4 Remove the chassis from the case for service Transition duct STEP 4 continued 6 Reinstall the room cabinet front by hooking the top over the rail along the chassis top Push it in at the bottom 7 Remove the air filters from room cabinet front 8 Slide the transition duct into place under the adapter and secure it with the two thumb...