Done
Hint!
The electrical cable must be long enough to allow the control top to be
removed via the switch bar.
10.3
Maintenance intervals
To ensure the highest operational reliability, all wearing parts should be replaced
at longer intervals.
The actual maintenance intervals can only be determined by the user since they
depend on the operating conditions, for instance:
•
daily period of use,
•
switching frequency,
•
type and temperature of the product,
•
type and temperature of the cleaning solution,
•
ambient conditions.
Maintenance intervals
Applications
Maintenance Intervals
(Guideline Values)
Elastomers
Maintenance Intervals
(Guideline Values)
TEFASEP gold (hard
seal)
Media at
temperatures of
60 °C to 130 °C
(140 °F to 266 °F)
approx. every 3 months
approx. every 12 months
Media at
temperatures of
< 60 °C
(< 140 °F)
approx. every 12 months
approx. every 12 months
10.4
Prior to disassembly
Prerequisite:
•
Make sure that during maintenance and repair work no process is in operation
in the area concerned.
Carry out the following steps:
1.
Drain all pipe system elements that lead to the valve and, if necessary, clean
or rinse them.
2.
Shut off the control air supply.
3.
Disconnect the power supply.
Maintenance
Maintenance intervals
430BAL008302EN_10
16.03.2023
39
Содержание VARIVENT N
Страница 62: ...13 Parts list shut off valve N Fig 43 Fig 44 Parts list shut off valve N 430BAL008302EN_10 62 16 03 2023...
Страница 70: ...14 Parts list shut off valve N_V Fig 45 Fig 46 Parts list shut off valve N_V 430BAL008302EN_10 70 16 03 2023...
Страница 75: ...15 Parts list shut off valve U Fig 47 Parts list shut off valve U 430BAL008302EN_10 16 03 2023 75...
Страница 76: ...Fig 48 Parts list shut off valve U 430BAL008302EN_10 76 16 03 2023...
Страница 83: ...16 Parts list shut off valve U_V Fig 49 Fig 50 Parts list shut off valve U_V 430BAL008302EN_10 16 03 2023 83...
Страница 86: ...17 Parts list shut off valve U_R Fig 51 Parts list shut off valve U_R 430BAL008302EN_10 86 16 03 2023...
Страница 87: ...Fig 52 Parts list shut off valve U_R 430BAL008302EN_10 16 03 2023 87...
Страница 94: ...18 Dimension sheet shut off valve N Fig 53 Dimension sheet shut off valve N 430BAL008302EN_10 94 16 03 2023...
Страница 96: ...19 Dimension sheet shut off valve U Fig 54 Dimension sheet shut off valve U 430BAL008302EN_10 96 16 03 2023...
Страница 103: ...Appendix 430BAL008302EN_10 16 03 2023 103...
Страница 104: ......