Damage to the pig cleaning station
Damage to the pig cleaning station can result in a malfunction.
► Observe the safety information sheets issued by the detergent
manufacturers!
► Only use detergents which are non-abrasive and not aggressive towards
stainless steel.
Notice
The cylinder pipe is made of PVDF
Aggressive cleaning agent can damage the cylinder pipe!
► Choose a suitable cleaning agent
► It is recommended that the cylinder pipe is replaced after 10 years.
Carry out the following steps:
1.
Disassemble the pig cleaning station, see “Disassembling the pig
actuator“ (Section 10.6, Page 47)
2.
Carefully clean the individual parts.
3.
Carefully clean all the threads on the initiators and screws.
®
Done
10.8.2 Lubricating Seals and Threads
Caution!
Damage to seals and threads
Damage to seals and threads can result in a malfunction.
► Ensure that an adequate film of lubricant is applied.
► For product contact seals only use suitable greases and oils
► Observe the safety information sheets issued by the lubricant
manufacturer!
Carry out the following steps:
1.
Lightly lubricate all threads.
2.
Grease all seals – including the O-rings at the top and bottom of the actuator
piston rod – very thinly.
®
Done
Maintenance
Maintenance
430BAL009974EN_3
23.07.2019
51