6.5.1
General
Danger
Live parts
Electrical shock can result in serious personal injury or death.
► Only allow properly qualified staff to carry out work on the electrical
equipment.
► Prior to establishing electrical connections check the maximum
permissible operating voltage.
Carry out the following steps:
1.
Connect in accordance with the connection plan and the information in the
corresponding instruction manual of the control top or in the data sheets of
the magnetic switch and initiators.
®
Done
Hint!
The proximity switches in the control top are factory set. During
transport and installation it can happen that the settings are changed,
so that readjustment may be required (see the Operating Instructions
for the control top).
6.5.2
Adjusting the initiators on the pig actuator
Prerequisite:
•
When adjusting the initiators (D1) there must not be no pig in the pig cleaning
station.
Carry out the following steps:
1.
Screw the threaded bushing (D4) onto the initiator (D1).
2.
Screw the initiators (D1) into the proximity switch holder (D).
Fig.16
Assembly and installation
Electrical connections
430BAL009974EN_3