6.3.2
Control Top with 2 Solenoid Valves
Fig.13:
Control top (standard variant in IP66)
E1
Exhaust air of the main stroke Y1 (sound absorber or exhaust air
throttle, optional)
Connection E1 must not be closed!
E2
Safety vent against excess pressure and exhaust air of lifting
actuators Y2 and Y3
Connection E2 must not be closed!
P
Central air supply with integrated filter
Optional: supply air throttle
N
Air connection for spring force backup
Only with logic element NOT
Y1
Air connection for external main stroke connection
with plug (23)
Y2
Air connection for lifting the valve disk
Y3
Air connection for lifting the double-disk or for the main stroke of an
external process valve
23
Plug
Control air pressure can be present at the plugs for the air
connections!
Before removing a sealing plug (23), make sure that the respective
air connection is pressure-free!
On most of the GEA Tuchenhagen valve types, solenoid valve Y1 internally
guides the main control air through the switch bar into the main actuator. The
external air connection Y1 is provided in addition.
The second solenoid valve is provided at connection Y2 or Y3, depending on its
use.
Assembly and installation
Pneumatic connections
430BAL010697EN_2
38
15.04.2020
Содержание T.VIS M-15
Страница 6: ...430BAL010697EN_2 6 15 04 2020...
Страница 53: ...Fig 27 Assembly and installation Electrical connections 430BAL010697EN_2 15 04 2020 53...
Страница 55: ...Fig 28 Assembly and installation Electrical connections 430BAL010697EN_2 15 04 2020 55...
Страница 111: ...14 Spare parts list Switch bar T VIS M 15 Fig 82 Spare parts list Switch bar T VIS M 15 430BAL010697EN_2 15 04 2020 111...
Страница 119: ...Appendix 430BAL010697EN_2 15 04 2020 119...
Страница 120: ......