Westfalia Separator
Mineraloil Systems GmbH
145
2051-9001-010
/
1205
5.4
Hood limit switch
Fig. 275
The hood limit switch 1
•
must
be installed for safety rea-
sons.
•
prevents the motor from being
switched on when the hood is open.
Technical data
Part-No. 0005-4416-280
Rated insulation voltage Ui
500 V
Conventional thermal current Ith
10 A
Ambient temperature
-35 °C to +85 °C (-31 – 185 °F)
Connecting cable (2 m)
V5F-5 x 0.75 mm² (18 AWG)
brown-blue
NO
contact
black-black
NC
contact
yellow/green
PE
Enclosure IP
67
Important instructions
In this version, the coil voltage of the power contactor is connected to the volt-
age between two external conductors of the three-phase network.
When installing a hood limit switch or an external emergency-off device, they
must be looped in at the connection points F1 (terminal 96) and contactor KM1
(terminal 14) (see section 5.1.1).
CAUTION: Danger to life through electrical voltage!
•
Disconnect the power supply to the electrical installation before connecting
the strands of the connecting line.
brown-blue = NO contact
The reset device following response of the motor protection can optionally be
set to
•
H = manual reset, i.e. the button must be pressed prior to the re-start.
•
A = automatic reset, i.e. the motor can be directly started by means of the ON
button.
When the bimetal release responds, the power contactor KM1 switches off the
motor.
Check the motor for overload or check the rated current setting at the bi-
metal release F1.
Содержание OTC 3-02-137
Страница 8: ...Westfalia Separator 8 Mineraloil Systems GmbH 2051 9001 010 1205 ...
Страница 38: ...Westfalia Separator 38 Mineraloil Systems GmbH 2051 9001 010 1205 ...
Страница 48: ...Westfalia Separator 48 Mineraloil Systems GmbH 2051 9001 010 1205 ...
Страница 136: ...Westfalia Separator 136 Mineraloil Systems GmbH 2051 9001 010 1205 ...
Страница 148: ...Westfalia Separator 148 Mineraloil Systems GmbH 2051 9001 010 1205 ...
Страница 150: ...Westfalia Separator 150 Mineraloil Systems GmbH 2051 9001 010 1205 Fig 278 ...
Страница 152: ...Westfalia Separator 152 Mineraloil Systems GmbH 2051 9001 010 1205 Fig 279 ...
Страница 154: ...Westfalia Separator 154 Mineraloil Systems GmbH 2051 9001 010 1205 Fig 280 ...
Страница 157: ...Westfalia Separator Mineraloil Systems GmbH 157 2051 9001 010 1205 ...
Страница 158: ...Westfalia Separator 158 Mineraloil Systems GmbH 2051 9001 010 1205 Fig 282 ...
Страница 160: ...Westfalia Separator 160 Mineraloil Systems GmbH 2051 9001 010 1205 Fig 283 ...
Страница 162: ...Westfalia Separator 162 Mineraloil Systems GmbH 2051 9001 010 1205 Fig 284 ...
Страница 164: ...Westfalia Separator 164 Mineraloil Systems GmbH 2051 9001 010 1205 ...
Страница 166: ...Westfalia Separator 166 Mineraloil Systems GmbH 2051 9001 010 1205 Fig 286 ...
Страница 168: ...Westfalia Separator 168 Mineraloil Systems GmbH 2051 9001 010 1205 Fig 287 ...
Страница 170: ...Westfalia Separator 170 Mineraloil Systems GmbH 2051 9001 010 1205 Fig 288 ...
Страница 172: ...Westfalia Separator 172 Mineraloil Systems GmbH 2051 9001 010 1205 Fig 289 ...
Страница 177: ...Westfalia Separator Mineraloil Systems GmbH 177 2051 9001 010 1205 ...
Страница 180: ...Westfalia Separator 180 Mineraloil Systems GmbH 2051 9001 010 1205 ...
Страница 181: ...Westfalia Separator Mineraloil Systems GmbH 181 2051 9001 010 1205 ...