5
Technical data
The operating safety of the delivered machine is only guaranteed if the machine
is used as intended according to the sections of the operating instructions and
the purchase order.
Warning!
Overload of the pump!
► Do not operate the pump above the maximum permissible operating
data.
► Avoid even short-term pressure overloads (e.g. by pressure surges).
5.1
Serial number
The pump can be uniquely identified by the serial number. When ordering spare
parts, always quote the serial number. The serial number is indicated on the type
plate.
5.2
Performance data
The performance data - delivery head and flow rate - are explained in accordance
with ISO 9906: 2012, Grade 3B and documented with the acceptance report.
5.3
Noise emissions
Measured values in accordance with DIN EN ISO 3746 for pump units,
measuring uncertainty 3 DB(A).
Noise emissions HYGIA I/II
Motor output [kW]
L
pfa
[dB(A)] 2-pole
L
pfa
[dB(A)] 4-pole
0.55
51
0.75
65
51
1.1
65
55
1.5
67
55
2.2
67
63
3.0
73
65
4.0
73
65
5.5
73
67
7.5
75
70
11.0
75
15.0
76
18.5
76
22.0
80
The noise emissions caused by a pump are influenced mainly by its application.
The values shown here should therefore be considered merely as a guide.
Technical data
Serial number
BA.H2A.KYY.001.GB_2
20