Alarms
11.1
Malfunctions and remedies
Notice!
Warning of damage to property/loss of product
Ignoring malfunctions may cause considerable damage to property and loss
of product. The safe operation of the valve in the event of a fault can no
longer be taken for granted and in the worst case can result in a loss of
sterility in the process.
► Make sure that malfunctions are quickly identified and promptly fixed.
In the event of malfunctions immediately deactivate the valve and secure it
against inadvertent reactivation. Malfunctions may only be remedied by qualified
staff, who must observe the safety instructions. For malfunctions not listed in the
table below, contact the manufacturer.
Malfunction
Cause
Remedy
Medium is leaking from the
clamp.
The housing seal is not fitted
correctly or damaged.
Fit the housing seal correctly
or replace it if damaged.
Medium is leaking from the
leakage holes of the internal
assembly.
The metal bellows on the
internal assembly is defective.
•
Replace the complete
internal assembly.
•
Send the defective internal
assembly to the
manufacturer for repair.
Medium exits at leakage hole
of the side valve.
•
Medium originates from
product side: O-ring seal
leaking.
•
Medium originates from
actuator: Actuator seals
leaking.
•
Replace the seals.
•
Check seal running
surfaces.
During pressure testing of the
internal assembly, air escapes
from the metal bellows.
The metal bellows on the
internal assembly is defective.
•
Replace the complete
internal assembly.
•
Send the defective internal
assembly to the
manufacturer for repair.
Leak at the valve seat.
•
The valve seat seal is
defective.
•
Product deposits on the
valve seat.
•
Replace the valve seat
seal.
•
Check the housing.
Alarms
Malfunctions and remedies
430BAL012841EN_1
07.03.2018
63