![GEA Aseptomag ADV Скачать руководство пользователя страница 51](http://html2.mh-extra.com/html/gea/aseptomag-adv/aseptomag-adv_operating-instruction_5081487051.webp)
•
Pressure regulating valve Ø 6 mm
•
Water bath
Carry out the following steps:
1.
Insert the internal assembly with the T-slot of the valve spindle of the removed
internal assembly into the pressurizing tool.
Fig.50:
Hook in the internal assembly
2.
Place the clamping arms of the pressurizing tool around the valve cap.
Fig.51:
Attach clamping arms
3.
Pull the valve cap against the seal by means of the star grip on the
pressurizing tool (hand-tight).
Maintenance
Carrying out the “Internal Assembly” Leak Test (Bubble Test)
430BAL012841EN_1
07.03.2018
51
Содержание Aseptomag ADV
Страница 68: ......