GE ZV900SLSS Скачать руководство пользователя страница 3

Access to Display Board, Motor, or Mini-Manual

The mini-manual is located behind the duct covers, 
on the front and left side of the  motor/blower housing.
To view the mini-manual, the duct covers must be
removed. See page 5 for instructions to remove the 
duct covers.

You can access the display board from the top, and the
motor from below, without taking the hood down or
removing the duct covers.

CAUTION:
Wear gloves to protect against sharp edges when
performing any procedure shown here. 

Service Information

The safety ON/OFF switch is located behind the filter(s)
and next to the motor. This switch controls power to the
entire hood.
• Remove the metal filter by grasping the handle, press

inward and pull down.

NOTE:

The filter can be reversed, with the handle on the

opposite side.

If the hood is installed for recirculating operation, a
charcoal filter will be present.
• Release the charcoal filter by removing thumbscrews

on each side of the charcoal filter.

These hoods must use WB02X11269 replacement
charcoal filters.

• Reach into the motor compartment and locate  the

ON/OFF switch. The light glows red when power is on.
Press to turn the power off. Power is off when the red
light goes out. 

Locate Safety ON/OFF Power Switch

• Unplug the bottom

connector from the 
hood motor.

• Remove 2 screws

on each side of
the blower.

• Slide the motor

back and out of
the keyhole slots.

To Remove the Blower/Motor

Connector

3

Содержание ZV900SLSS

Страница 1: ...ENTIAL AND PROPRIETARY INFORMATION NOT FOR PUBLIC DISCLOSURE DESIGN INFORMATION Lighted electronic push button controls with LCD display 4 speed fan control 4 level lighting control and 570 CFM Designed for vented operation but can be easily converted for recirculating operation No kits required ZV900SLSS Wall Mount Chimney Hood shown Vent holes at the top of the duct covers indicate the hood is s...

Страница 2: ...el used The buttons allow you to cycle around to the desired setting There are four light levels settings and OFF 3 LIGHT INCREASE ON OFF Press to turn on and brighten the lights It remembers the last light level used The buttons allow you to cycle around to the desired setting There are four light levels settings and OFF 4 DISPLAY Shows the fan setting 5 FAN DECREASE ON OFF Press to turn on and d...

Страница 3: ...ontrols power to the entire hood Remove the metal filter by grasping the handle press inward and pull down NOTE The filter can be reversed with the handle on the opposite side If the hood is installed for recirculating operation a charcoal filter will be present Release the charcoal filter by removing thumbscrews on each side of the charcoal filter These hoods must use WB02X11269 replacement charc...

Страница 4: ...ing it free NOTE Do not remove the outer trim ring lamp assembly 2 Grasp the bulb and pull it straight out 3 Replace with the same wattage type and size bulb Wear gloves Do not touch bulb with your bare fingers 4 Replace inner cover by inserting the three retaining tabs into the three slots and pressing them firmly in place NOTE If WRONG WATT BULB appears in the display the wrong type of replaceme...

Страница 5: ...ieces of each duct piece Remove 3 screws on each side of the bottom dust cover Gently press in at the side seams to disengage the front piece Lift front piece off then lift rear panel off ZV900 Wall Mount Hood Use a small flat blade screwdriver to pop the top trim strips out of the track on both sides Remove screw and duct holding bracket on each side Press in on the lower trim strips to lift the ...

Страница 6: ...ms Gray Blue High speed 10 Ohms Black Blue Boost 6 5 Ohms Halogen Lights Voltage from the board to the primary of the transformer varies depending on the light setting The dimmer for the halogen lights is a pulse width modulated 120 VAC signal at 30 kHz Check the voltage on the primary transformer the two terminals on the bottom of the PCB just left of center Light Setting VAC 1 65 2 90 3 105 4 Br...

Страница 7: ...7 ZV900 Wall Mount Chimney Hood WARNING POWER MUST BE DISCONNECTED BEFORE SERVICING THIS HOOD ...

Страница 8: ...ZV925 Island Hood WARNING POWER MUST BE DISCONNECTED BEFORE SERVICING THIS HOOD ...