Deluxe models

Special corrosion-protected units

To help extend the life of the Zoneline unit in seacoast areas, some 
Deluxe Zoneline units may be ordered with a special corrosion  
protection treatment on outdoor components and use stainless  
steel hardware. Zoneline units with optional corrosion protection  
have a ‘C’ in the 10th character of the model number.

Internal condensate removal

Available on the 900 and 5800 heat pumps, this feature drips the  
heat pump condensate over the warm indoor coil to help dissipate 
water from heat pump operation and associated defrost cycles. The 
installation of an internal or external drain system is recommended if 
no dripping of condensate to the outdoors is desired. ICR must not be 
installed in seacoast or corrosive applications.

The Dry Air 5

The Dry Air 5 features innovative technology from Heat Pipe 
Technology, Inc., an addition which enables this unit to remove 5% 
more moisture from the air than standard GE Zoneline

®

 models. The 

Dry Air 5 system, Heat Pipe, is a hermetically sealed heat transfer 
surface that is saddlebagged around the indoor coil (evaporator) of 
the Zoneline. This coil arrangement will transfer heat from one coil to 
another without power consumption. This assembly uses R- as the 
refrigerant and is isolated from the regular Zoneline refrigerant circuit.

As warm humid air is pulled through the pre-cool section of the Heat 
Pipe, the heat removed from the air is absorbed by the refrigerant, 
causing the refrigerant to boil. As the pre-cooled air passes through  
the Zoneline evaporator, the air is further cooled (colder than it would 
be normally), removing 5% more moisture from the air than standard 
GE packaged terminal air conditioners.

As the cold air passes through the reheat section of the Heat Pipe, the 
refrigerant condenses and the liquid flows back to the pre-cool section 
to be reheated again. The air discharged into the room by this process 
is much drier, creating a more comfortable room condition. 

Electronic  

temperature limiting

Preset cooling and heating 

limits with 7 independent 

cooling and 7 heating 

limits—saves energy by 

preventing over-cooling  

or over-heating of rooms.

“Smartfan”  

fan cycle selection

Select fan cycle or fan 

continuous independently 

for heating and cooling.

Solid-state  

thermostat control

 

Provides better room  

temperature control  

vs. electromechanical  

temperature control 

device. 

Freeze Sentinel

 

Provides automatic  

protection against  

freezing by switching  

the unit to heat should  

the temperature of an  

unoccupied room drop 

to 1°F.

Heat Sentinel

 

Provides automatic  

protection against  

overheating by switching 

on the unit to cool should 

the temperature of  

an unoccupied room 

reach 85°F.

Auto frost control

A special sensor monitors 

the roomside coil to  

prevent efficiency-robbing 

accumulation of frost  

during cooling operation.

GE Dry Air 25

  

(not shown)  

Innovative technology from 

Heat Pipe Technology, Inc

enables the DryAir 5 to 

remove 5% more moisture

from the air than standard 

GE packaged terminal air 

conditioners.

Universal power cord

Flexibility of heat  

applications. All 

Zonelines contain a 

bank of  heaters.

900 series and Dry Air 5 series – heat/cool units

900 series – heat pump unit

Highly featured microcomputer controls

Central desk control  

compatible 

Ability to turn the unit  

“on” or "off" from a  

remote location.

Two fan motors

  

(not visible) 

Separate motors for  

indoor and outdoor fans  

to assure quiet operation.

Reversible louver

  

(not shown) 

May be reversed to  

provide an air discharge  

angle of 0 or 50 degrees  

off vertical with the simple 

removal of six screws.

3-Position vent control

 

(not shown) 

Opens vent. Provides up  

to 75 cfm of outdoor air.  

The closed position saves  

energy by recirculating  

conditioned room air.

Reverse cycle defrost 

 

(not shown) 

Solid-state sensor  

monitors frost build-up  

on outdoor coil. When 

frost is detected, the 

refrigerant flow is reversed 

to melt frost build-up. 

When completed, the 

refrigerant is reversed to 

the normal energy-saving 

heat pump operation for 

additional heat pump  

operating hours.

Easy-access filter

  

(not shown) 

Two upfront interchangeable 

filters are part of roomside 

cabinet for easy access 

and maintenance.

Remote control  

compatible

 

Ability to be controlled  

by a wall-mounted  

thermostat with high  

or low fan speed.

Rotary compressor

 

Fewer moving parts  

than reciprocating models  

for quiet, reliable operation 

and longer life.

Touch pad controls

 

With electronic control 

temperature display. Gives  

the user finer control over  

the temperature.

Содержание Zoneline Premium AZ58H09D

Страница 1: ...GE Zoneline packaged terminal air conditioners ...

Страница 2: ... ...

Страница 3: ...nd apartments All Zoneline units feature the exclusive GE Superseal system which minimizes energy usage by reducing air infiltration The result is maximum operating efficiency and a more comfortable room All Zoneline units are also very quiet thanks to a lower sound level and lower sound transmission The newest innovation in Zoneline units is the Dry Air 25 Series Similar to our Deluxe 2900 Series...

Страница 4: ...its are equipped with microcomputer touch controls This feature gives the user better control over the temperature with a touch pad and an LED readout Optional corrosion treatment Deluxe Zoneline units can be ordered with special treatment to reduce the effects of corrosive environments Special treatments are placed on the outdoor coil and other components to extend the life of the unit Remote ins...

Страница 5: ...om the air than standard GE packaged terminal air conditioners The Dry Air 25 is perfect for high humidity climates Available on 7000 9000 and 12000 BTU models Upfront filters For ease of cleaning all Zoneline units have interchangeable removable upfront filters made of long lasting nylon mesh thus assuring high performance and long life Electronic temperature limiting Heating and cooling temperat...

Страница 6: ...of cleaning Long lasting nylon mesh Central desk control compatibility Remote thermostat capability Smartfan Fan cycle operation based on heat cool selection Deluxe Dry Air 25 series cooling with resistance heat Includes all features of 2900 series plus Removes 25 more moisture from the air than standard GE packaged terminal air conditioners Cool and dry air in less time than standard Zoneline mod...

Страница 7: ...e control Standard Standard Standard Standard Fan Only setting 2 speed Hi Low Hi Low Hi Low Hi Low Indoor fan speed Hi Low Hi Low Hi Low Hi Low Cool heat only settings Hi Low Auto Hi Low Auto Hi Low Auto Hi Low Auto Staged heating 3 stage 3 stage Freeze Sentinel Standard Standard Standard Standard Heat Sentinel Standard Standard Standard Standard Temperature limiting Electronic 7 step Electronic 7...

Страница 8: ...eating of rooms Smartfan fan cycle selection Select fan cycle or fan continuous independently for heating and cooling Solid state thermostat control Provides better room temperature control vs electromechanical temperature control device Freeze Sentinel Provides automatic protection against freezing by switching the unit to heat should the temperature of an unoccupied room drop to 41 F Heat Sentin...

Страница 9: ...mperature control device Freeze Sentinel Provides automatic protection against freezing by switching the unit to heat should the temperature of an unoccupied room drop to 41 F Heat Sentinel Provides automatic protection against overheating by switching on the unit to cool should the temperature of an unoccupied room reach 85 F Room occupancy sensor compatible Ready for connection to room occupancy...

Страница 10: ...ity RAK3153 3203 230 208 volt line cord connection kit RAK4157 4207 4307 230 208 volt universal power supply kit RAK5157 5207 5307 265 volt universal power supply kit 230 208 volt Line cord connected units LCDI Power Connection Kit RAK3153 RAK3203 RAK3303 Heater KW 2 55 2 09 3 45 2 82 5 00 4 09 Watts 2 550 2 090 3 450 2 820 5 000 4 090 BTUH 8 600 7 100 11 700 9 600 17 000 13 900 Amps 11 6 10 6 15 ...

Страница 11: ...50 13 400 6 400 6 200 8 400 8 200 10 900 10 700 13 800 13 800 COP 3 6 3 6 3 6 3 6 3 4 3 4 3 2 3 2 3 7 3 7 3 6 3 6 3 4 3 4 3 2 3 2 Watts 520 505 695 675 950 925 1 275 1 245 505 490 685 670 940 920 1 265 1 235 Amps 2 4 2 6 3 2 3 5 4 3 4 7 5 8 6 3 2 4 2 5 3 2 3 4 4 3 4 7 5 7 6 2 Weight Net Ship 102 117 105 120 113 128 123 138 108 122 113 128 118 133 127 142 Sound Transmission Class STC 29 29 29 29 29...

Страница 12: ...Solenoids Circuit Boards Auxiliary Controls Thermistors Freeze Sentinel Frost Controls ICR Pump Capacitors Varistors and Indoor Blower Bearing if any of these parts should fail due to a defect in materials or workmanship During this additional four year limited warranty you will be responsible for any labor and related service costs See written warranty for details The Zoneline chassis is identifi...