Quick Heat Recovery

Activates each time the thermostat is 
switched from 

STOP

or a 

COOL

mode to a 

HEAT

mode. Electric heaters are energized until the
thermostat set point is reached. On heat pump
models, the heat pump operation will resume 
at the next call for heat.

Safety Instructions

Operating Instructions

Care and Cleaning

Tr

oubleshooting T

ips

Consumer Support

3

Controls

Temp Control

The temp control is used to maintain the
room temperature. The compressor will
cycle on and off to keep the room at the
same comfort level. When you turn the
knob to 

COOLER

(blue), the indoor air 

will become cooler. Turn the knob to

WARMER

(red) and the indoor air will

become warmer.

3800 Series only

When the outdoor temperature is lower
than 20°F, heat is provided by the electric
heater in the air conditioner instead of by
the heat pump.

Mode Control

HIGH COOL

and 

LOW COOL

provide cooling

with different fan speeds.

HIGH HEAT

and 

LOW HEAT

provide heating

with different fan speeds.

LOW FAN

or 

HIGH FAN

provides air

circulation and filtering without cooling 
or heating.

NOTE: 

If you move the switch from a cool or heat

setting to STOP or to a fan setting, the unit has an
automatic 3-minute delay before allowing the
compressor to restart in the cool or heat mode.

TEMP CONTROL

MODE CONTROL

About the controls on your Zoneline.

ge.com

About Your Heat Pump (3800 Series only)

Heat pumps can save money by removing heat
from the outside air—even when the outside
temperature is below freezing—and releasing
that heat indoors.

To get the best performance from your heat
pump, don’t change the room thermostat very
often. Raising the heat setting 2–3 degrees will
cause the Zoneline to use its electric heating
elements in order to reach the new temperature
setting quickly.

There is a three minute minimum compressor
run time at any setting to prevent short cycling.

The indoor fan motor starts before the
compressor and stops after the compressor 
cycles off.

The electric heating elements use much 
more electricity than heat pumps and cost 
more to operate.

Содержание Zoneline AZ28E09DAB

Страница 1: ...port Consumer Support Back Cover Warranty 27 Heat Cool Model 2800 Heat Pump Model 3800 Owner s Manual and Installation Instructions ge com Write the model and serial numbers here Model _______________...

Страница 2: ...ck of this manual Replace immediately all electric service cords that have become frayed or otherwise damaged A damaged power supply cord must be replaced with a new power supply cord obtained from th...

Страница 3: ...LOW HEAT provide heating with different fan speeds LOW FAN or HIGH FAN provides air circulation and filtering without cooling or heating NOTE If you move the switch from a cool or heat setting to STOP...

Страница 4: ...t be removed from the vent door before use See the Installation Instructions in the back of this manual Air Direction To adjust the air direction remove the room cabinet Remove the 7 louver screws tha...

Страница 5: ...mit 1 Cool TL2 C Temp Limit 2 Cool TL3 C Temp Limit 3 Cool 7 8 Heat Sentinel HEAT BOOST 3800 Series models only Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consum...

Страница 6: ...bled UP it turns OFF the freeze sentinel protection feature With the switch disabled DOWN the freeze sentinel is activated which automatically provides heat without user interface This helps to preven...

Страница 7: ...3 1 2 76 85 Temperature limiting during HEAT mode all temperatures shown in F UP DOWN Minimum Maximum NONE 4 5 6 60 85 4 5 6 60 80 4 5 6 60 78 5 4 6 60 76 5 6 4 60 74 4 5 6 NONE 60 72 4 6 5 60 70 6 4...

Страница 8: ...bottom of the terminals and tighten screws securely After all desired connections have been made replace the access cover and room cabinet The owner is responsible for making all connections and setti...

Страница 9: ...d the unit will be controlled by a remote thermostat NOTE The number 4 dip switch must be in the enabled UP position to activate the remote thermostat See the installation instructions supplied with t...

Страница 10: ...ve the four screws securing the unit flanges to the case Slide the unit from the wall case Grasp the vent filter tab and pull the filter out by sliding it to the right To clean the vent filter Run wat...

Страница 11: ...er through the filters from the back side Dry thoroughly before replacing NOTE The air filters are interchangeable and will fit in either the right or left side To remove the air filters To replace th...

Страница 12: ...or local codes and ordinances For personal safety this Zoneline must be properly grounded Protective devices fuses or circuit breakers acceptable for Zoneline installations are specified on the namep...

Страница 13: ...ere not designed for your new GE Zonelines The RAK40 contains air deflectors and gaskets that mount to the unit to direct the hot exhaust air away from the air intake to allow the unit to function pro...

Страница 14: ...ler to ensure the connection of components is done in accordance with these instructions and all electrical codes Branch Circuit and Proper GE Unit Amperage Rating Subbase Kit 15 RAK204D15P 20 RAK204D...

Страница 15: ...vailable to provide a flexible enclosure for direct connection The instructions provided with the selected subbase kit must be carefully followed It is the responsibility of the installer to ensure th...

Страница 16: ...tion box to attach conduit coming from the branch circuit Remove the knockout attach the conduit and bring wires into the junction box Leave 6 of wire free at the end of the conduit to allow connectio...

Страница 17: ...r 5 00 4 10 KW 230 208 Volt Heater Wattage Power Supply Kits 230 208 Volts Circuit Protective Device RAK4157 2 55 KW 2 09 KW 15 Amp Time Delay Fuse or Breaker RAK4207 3 45 KW 2 82 KW 20 Amp Time Delay...

Страница 18: ...ies wall cases are insulated Insulation kit RAK901L is available for use with RAB77 or existing uninsulated wall cases when needed NOTE For installation with a subbase or duct adapter see the instruct...

Страница 19: ...e top over the rail along the unit top 1 then pushing it in at the bottom 2 4 Installation Instructions 19 NOTE There are several extra holes in the unit side flanges for installation in wall cases ot...

Страница 20: ...g onto external building walls we recommend the use of RAD10 Drain Kit External Drain See the Installation Instructions in the RAD10 kit Internal Drain See the Installation Instructions in the RAD10 k...

Страница 21: ...plug If the RESET button will not stay engaged discontinue use of the Zoneline and contact a qualified service technician Zoneline does not cool Indoor airflow Make sure there are no curtains blinds...

Страница 22: ...witch for cooling and one switch for heating The air does not feel The heat pump alone Use the Electric Heat Option This turns off the warm enough during produces air that feels heat pump and warms wi...

Страница 23: ...ear a fan noise stop and start You may notice a few minutes delay in starting if you try to restart the Zoneline too soon after turning it off or if you adjust the thermostat right after the compresso...

Страница 24: ...24 Notes Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety Instructions...

Страница 25: ...25 Notes ge com Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer Support...

Страница 26: ...26 Notes Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety Instructions...

Страница 27: ...ct or due to unreasonable use including failure to provide reasonable and necessary maintenance Failure or damage resulting from corrosion due to installation in a coastal environment except for model...

Страница 28: ...call 800 TDD GEAC 800 833 4322 Parts and Accessories ge com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discov...

Отзывы: