– 19 –
Compressor
Run diagnostic mode
12
to test the circuit
between the power supply board, compressor,
and the condenser fan. (
See
Diagnostics and
Service Information
.)
Voltage at L2 to N at the wiring junction box
should be 120 VAC.
Compressor resistance values:
Common to start - 6
Ω.
Common to run - 4
Ω.
R
S
C
Run Capacitor
The run capacitor is located in the middle of the
machine compartment between the compressor
and the condenser fan assembly. It is threaded
into the machine compartment base-plate.
To remove the run capacitor, disconnect
the wiring at the junction box and turn
counterclockwise until free.
Check for shorted or open condition on the
capacitor's blue and red wires at the junction box.
Water Valve
The water valve is located on the right side of the
machine compartment in front of the condenser. It
is attached by a single 7-mm hex-nut.
Water Valve
Check for 120 VAC at K2 on the power supply
board when the icemaker is in fi ll mode.
Resistance should be approximately 182
Ω.