background image

Installation Instructions

REQUIREMENTS FOR ALCOVE OR 

CLOSET INSTALLATION

MOBILE OR MANUFACTURED HOME 

INSTALLATION

3

- Explosion Hazard

WARNING

Keep flammable materials and vapors, such as gasoline, 

away from dryer.
Place dryer at least 18” (46 cm) above the floor for a 

garage installation.
Failure to do so can result in death, explosion, or fire.

 

Installation must conform to the 

MANUFACTURED HOME CONSTRUCTION AND 

SAFETY STANDARD, TITLE 24, PART 32–80 or 

Standard CAN/CSA-Z240 MH, or, when such 

standard is not applicable, with AMERICAN 

NATIONAL STANDARD FOR MOBILE HOME,  

ANSI/NFPA NO. 501B.

 

The dryer MUST be vented to the outdoors. The 

exhaust vent must be securely fastened to a 

non-combustible portion of the mobile home.

 

The vent MUST NOT be terminated beneath a 

mobile or manufactured home.

 

The vent duct material MUST BE METAL.

 

KIT 14-D346-33 MUST be used to attach the dryer 

securely to the structure.

 

The vent MUST NOT be connected to any other 

duct, vent or chimney.

 

Do not use sheet metal screws or other 

fastening devices which extend into the interior 

of the exhaust vent.

 

Provide an opening with a free area of at least 

25 square inches for introduction of outside air 

into the dryer room.

 

See the sections for electrical connection 

information. 

 

If the dryer is approved for installation in an 

alcove or closet, it will be stated on a label on the 

dryer back.

 

The dryer MUST be vented to the outdoors. See 

the EXHAUSTING THE DRYER section.

 

Minimum clearance between dryer cabinet and 

adjacent walls or other surfaces is:

    0” 

either 

side

    3” 

front

    3” 

rear

     

52” from floor to overhead cabinets

 

Consideration must be given to provide adequate 

clearance for installation and service.

 

Closet ventilation openings required: 2 louvers 

each 60 square inches (387 square cm), located 3 

inches (7.6 cm) from top and bottom of door.

NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT 

THE REAR OF THE DRYER, MINIMUM CLEARANCE 

FROM THE WALL IS 5.5 in.

Gas Dryers Only:

 

No other fuel burning appliance shall be installed 

in the same closet as a gas dryer.

 

The dryer must be disconnected from the gas 

supply piping during pressure testing at pressures 

greater than ½ psi (3.5 kPa).

 

A 1/8 inch NPT minimum plugged tapping, 

accessible for test gauge connection, must be 

installed immediately upstream of the gas supply 

connection to the dryer.

MINIMUM CLEARANCE OTHER THAN 

ALCOVE OR CLOSET INSTALLATION

Minimum clearance to combustible surfaces and 

for air opening are: 0” both sides, 1” front, 3” rear 

and 1” top. Consideration must be given to provide 

adequate clearance for installation and service.

Содержание WX9X2

Страница 1: ...s dryer installation must be performed by a qualified installer Install the clothes dryer according to these instructions and local codes DO NOT install a clothes dryer with flexible plastic venting m...

Страница 2: ...at 800 626 2002 during normal business hours Part Number Accessory WE25M53 Complete Kit hoses Y adapter washers included OR WE1M847 Long Hose and WE1M848 Short Hose PM14X10056 Dryer door opening vent...

Страница 3: ...o the dryer room See the sections for electrical connection information If the dryer is approved for installation in an alcove or closet it will be stated on a label on the dryer back The dryer MUST b...

Страница 4: ...ng to one male end of the Y connector Tighten by hand until firmly seated 5 Ensure the rubber flat washer is in place and attach the dryer s long inlet hose to the other male end of the Y connector Ti...

Страница 5: ...er cord is unplugged from the wall Turn the dryer s gas shut off valve in the supply line to the OFF position Disconnect and discard old flexible gas connector and ducting material Shut off Valve MATE...

Страница 6: ...t be adjusted for operation at or below 2000 ft elevation For operation at elevations above 2000 ft input ratings should be reduced at a rate of 4 percent for each 1000 ft above sea level Installation...

Страница 7: ...f valve F Apply pipe compound or PTFE tape to all male threads Shut Off Valve Plugged Tapping CONNECTING THE DRYER TO THE GAS SUPPLY Install a female 3 8 NPT elbow at the end of the dryer gas inlet In...

Страница 8: ...l Code CSA C22 1 This appliance must be supplied with 120V 60Hz and be connected to a properly grounded branch circuit protected by a 15 or 20 amp circuit breaker or time delay fuse If electrical supp...

Страница 9: ...OFF THE TERMINAL BLOCK Slip joint pliers Flat blade crewdriver Phillips screwdriver Level TOOLS YOU WILL NEED MATERIALS YOU WILL NEED 4 dia metal elbow 3 4 strain relief UL recognized 4 duct clamps 2...

Страница 10: ...re or electrical shock GROUNDING INSTRUCTIONS For a grounded cord connected dryer This dryer must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shoc...

Страница 11: ...120 240V 30A power supply cord kit marked for use with dryers and provided with closed loop or spade terminals with upturned ends not supplied Hot Wire Hot Wire Green Wire Relocatre green ground screw...

Страница 12: ...l length of flexible metal duct should not exceed 7 9 2 4 m For many applications installing elbows at both the dryer and the wall is highly recommended see illustrations at right Elbows allow the dry...

Страница 13: ...s all the straight portions and elbows of the system transition duct included EXHAUST LENGTH 13 DO NOT bend or collapse ducting Use elbows if turns are necessary DO NOT use excessive exhaust length Cu...

Страница 14: ...uld present minimal resistance to the exhaust airflow and should require little or no maintenance to prevent clogging Wall caps must be installed at least 12 above ground level or any other obstructio...

Страница 15: ...LBOW AND DUCT FOR EXHAUST TO LEFT OR RIGHT SIDE OF CABINET Preassemble 4 elbow with 4 duct Wrap duct tape around joint QVHUW GXFW DVVHPEO HOERZ UVW WKURXJK WKH side opening and connect the elbow to th...

Страница 16: ...safety hazard 16 DUCT TAPE ADDING ELBOW FOR EXHAUST THROUGH BOTTOM OF CABINET Insert the elbow through the rear opening and connect it to the dryer internal duct Apply duct tape as shown on the joint...

Страница 17: ...ndio La instalaci n de la secadora debe efectuarla un instalador calificado Instale la secadora de ropa de acuerdo con estas instrucciones y en cumplimiento con los c digos locales NO instale una seca...

Страница 18: ...ndo al 800 626 2002 durante el horario comercial habitual N mero de Pieza Accesorio WE25M53 Kit Completo mangueras lavadora con adaptador en Y incluido O WE1M847 Manguera Larga y WE1M848 Manguera Cort...

Страница 19: ...instalaci n de su secadora en alcoba o armario esto figurar en una etiqueta en el reverso de la secadora Esta secadora DEBE tener una ventilaci n al exterior Ver la secci n SALIDA AL EXTERIOR DE LA SE...

Страница 20: ...e a mano hasta que est firmemente asentada 5 Aseg rese de que la arandela plana de goma se encuentre en su lugar y sujete la manguera larga de entrada de la secadora al otro extremo macho del conector...

Страница 21: ...riente Gire a la posici n OFF apagado la v lvula de gas de la secadora de la l nea de suministro Desconecte y elimine el conector flexible de gas y el material del conducto V lvula de cierre MATERIALE...

Страница 22: ...N Los niveles de entrada de las secadoras de ropa a gas est n basados en el funcionamiento al nivel de mar y no necesitan ajustes para funcionar en o por debajo de los 2000 pies de elevaci n Para un...

Страница 23: ...en todas las roscas macho V lvula de apagado Toma a rosca C MO CONECTAR LA SECADORA AL SUMINISTRO DE GAS Instale un codo hembra NPT de 3 8 al final de la entrada de gas de la secadora Instale un adap...

Страница 24: ...utilice una llama abierta para detectar p rdidas de gas Controle todas las conexiones con una soluci n jabonosa o un elemento equivalente Aplique una soluci n jabonosa La soluci n para controlar p rdi...

Страница 25: ...el tomacorriente de la vivienda antes de comprar el cable 4 Placa de cubierta Kit WE1M454 C MO CONECTAR UNA SECADORA ELECTRICA S ltese si se trata de las secadoras a gas o si su secadora ya tiene un...

Страница 26: ...STRUCCIONES DE CONEXI N A TIERRA Para una secadora conectada con cable con conexi n a tierra Esta secadora deber estar conectado a tierra En caso de mal funcionamiento o aver a la conexi n a tierra re...

Страница 27: ...tores de cobre 10 AWG m nimo o kit de cable de suministro de energ a de 120 240V 30A marcado para su uso con secadoras y provisto con terminales de bucle cerrado o hembra con extremos hacia arriba no...

Страница 28: ...tos La longitud total del conducto de metal flexible no deber superar los 7 9 2 4 m Para muchas aplicaciones se recomienda enf ticamente la instalaci n de codos tanto en la secadora como en la pared L...

Страница 29: ...de escape incluye todas las porciones rectas y todos los codos del sistema incluyendo el ducto de transici n LONGITUD DE SALIDA NO doble o pliegue los conductos Utilice codos si algunos codos resultan...

Страница 30: ...ia m nima al flujo de salida y debe requerir poco mantenimiento para evitar las obstrucciones Las cubiertas de pared deben instalarse por lo menos a 12 sobre el nivel del suelo o cualquier otra obstru...

Страница 31: ...Cierre la abertura trasera con la placa protectora Kit WE1M454 Desconecte la secadora del suministro el ctrico Use guantes y protectores para brazos Si esto no se cumple se podr producir una incendio...

Страница 32: ...nte Introduzca el codo a trav s de la abertura trasera y con ctelo al conducto interno de la secadora Aplique cinta aislante como puede verse en la junta entre el conducto interno de la secadora y el...

Отзывы: