– 26 –
Drive Motor Tumbles Slowly
Bleach Dispenser Does Not Operate
184 Ohms +/-7%
Defective
Speed Control
Board
Remove lower front panel.
Check motor and tachogenerator
resistances.
(see schematic)
Drive motor tumbles
very slowly in any
timer position
Readings other than
184 Ohms +/-7%
Defective
Drive Motor
GEA00594
NOTE: Always check wiring
to components.
NOTE: Bleach dispenser on
timer flow charts is V2, and
softner dispenser is V1.
Bleach dispenser
does not operate
120VAC
0
Washer Completely
Inoperative
Washer Completely
Inoperative
Advance the timer to the start of the
rinse cycle. Pull the timer knob and
allow the washer to start to fill.
Measure the voltage drop across the
bleach solenoid terminals
GEA00593