1.  Product Description 

 
The  W iMAX SmartMeter by GE (W X-I210+c)  is an electronic, single-phase electricity meter 
intended for residential metering and demand response applications.  The meter can be 
operated in demand / load profile (DMD / LP), or time-of-use / load profile (TOU / LP)  mode, 
thereby providing support for a broad range of advanced metering and demand response 
requirements. 
 
The  W X-I210+c  is  a new class of meter that contains  an integrated  W iMAX

1

  / HomePlug

2

 

router, which provides open standards-based communications network interfaces for both 
remote meter communications and meter-to-home area network (HAN) communications over 
premise  electric wiring. 
 

 

Figure 1-1: WX-I210+c: WiMAX SmartMeter by GE 

 
The  WX-I210+c  incorporates  a wide range of additional advanced metering features including: an 
extended range of software-configurable  metrology  capabilities (soft-switches); accurate timekeeping 
via a harmonic clock  with  an oscillating crystal and battery backup power source,  to  accurately 
maintain time during power outage conditions; enhanced energy, demand, and time-of-use billing 
measures; load profile recording; self-read capability; demand reset support; test mode; real-time 
pricing functionality; demand response and load limiting functionality with the presence of optional 
relay switch; authorized local connect / disconnect switch control; and rolling status and rolling billing 
period functions. 

 

                                                

1

 IEEE 802.16.e  Air Interface for Fixed and Mobile Broadband Wireless Access Systems (WiMAX) 

2

 HomePlug Powerline Alliance, HomePlug version 1.0 

Содержание WiMAX WX-I210+c

Страница 1: ...WiMAX SmartMeter by GE Basic Manual WX I210 c WiMAX SmartMeter by GE ...

Страница 2: ...tion 1 2 Installation Instructions 2 3 Labels and Display Information 3 3 1 Nameplate Information and Labels 3 3 2 Liquid Crystal Display Information 4 3 2 1 Display Examples 5 4 Service and Repair 7 4 1 Service 7 4 2 Repair 7 4 3 Returning a Meter 7 ...

Страница 3: ...ure 1 1 WX I210 c WiMAX SmartMeter by GE The WX I210 c incorporates a wide range of additional advanced metering features including an extended range of software configurable metrology capabilities soft switches accurate timekeeping via a harmonic clock with an oscillating crystal and battery backup power source to accurately maintain time during power outage conditions enhanced energy demand and ...

Страница 4: ...the following installation steps are performed 1 Take the last meter read on the existing meter 2 Remove existing meter s tamper indication seal 3 Remove existing meter from socket 4 Replace new meter into socket 5 Install new tamper indication seal 6 Re energize the circuits to the meter ...

Страница 5: ...3 1 for a graphic representation of the meter nameplate The meter nameplate is found on the front of the meter Figure 3 1 Meter Nameplate The nameplate provides the following information Meter type Utility information and bar code area Meter serial number Operating frequency Test ampere value Watt hour and test constants Current and voltage rating Wiring configuration ANSI form factor Available so...

Страница 6: ...played when the meter is operating in TOU Mode If no letters are lit the meter is in a non TOU rate 6 This display indicates an end of interval EOI condition 7 When displayed the A annunciator indicates the A voltage is present at the meter If this annunciator is blinking phase A voltage is low The B annunciator will only be displayed during an all segments display When displayed the C annunciator...

Страница 7: ...e states change in decreasing order Note If the calculated phasor VAh is below the programmed creep threshold the meter will turn off the Wh and VArh direction arrows 9 These characters display the programmed metering quantities There are three possible decimal point positions located between the four rightmost digits 3 2 1 Display Examples The following figures show examples of WiMAX SmartMeter d...

Страница 8: ...e Figure 3 4 Alternate Display Figure 3 4 shows the following conditions 1 Meter is in Alternate Display mode 2 Display label 108 is displayed 3 Phase A and C voltages are present 4 Six digit display of quadergy kVArh 5 Displayed quantity is measured in kVArh 6 Meter is displaying previous season data 7 The two blocks indicate State 1 of the magnitude indicator 8 Quadergy kVArh is leading 9 Energy...

Страница 9: ... design the repair of on board components is not recommended Instead return the whole meter to General Electric as described in the following paragraph 4 3 Returning a Meter If you wish to return a meter call your General Electric sales representative for a Returned Material Authorization RMA The entire meter should be returned with the GE supplied Returned Material Authorization information form ...

Отзывы: