background image

WARRANTY

WHAT IS COVERED?

Full Five Year Parts Warranty from date of original proof of
purchase. We will provide, free of charge, a replacement part
that fails due to manufacturing defect in material or workmanship,
when installed and used as directed in the User’s Guide.

This warranty is extended to the original purchaser for products
purchased for ordinary home use.

GE Bath Fan Hot Line

1-800-684-9975

FOR TECHNICAL ASSISTANCE

AND / OR QUESTIONS.

Read your User’s Guide.

 

If you have any questions about operating the product, please contact your dealer.

Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states
do not allow limitations on how long an implied warranty lasts, so these exclusions or limitations may not apply to you. This
warranty gives you specific legal rights and you may have other rights which vary from state to state and province to province.

WHAT IS NOT COVERED?

• Installation services or service trips to your home to teach

you how to use the product.

• Labor costs or the cost of replacement components as part

of routine maintenance.

• Failure or defects in product arising from Improper installation

If you have an installation problem, contact your dealer or
installer. You are responsible for providing adequate
electrical, exhausting and other connecting facilities. See
the Installation Instructions provided with this product for
electrical, exhaust and connection details.

• Replacement of house fuses or resetting of circuit breakers.

• Failure of the product if it is used for something other than

the intended purpose of manufacturer or used commercially.

• Damage to the product caused by accident, fire, floods,

acts of customer, or acts of God.

This warranty contains the sole and exclusive warranty of GE for claims based on defects in these products. Upon the expiration
of the warranty period, all such liability shall terminate. There are no other warranties, whether written, oral, implied or
statutory. NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE SHALL APPLY.

IN NO EVENT SHALL GE BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL, INDIRECT, OR INCIDENTAL DAMAGES, SUCH AS, BUT
NOT LIMITED TO, LOSS OF PROFIT OR REVENUES, LOSS OF USE OF THE PRODUCTS OR ANY ASSOCIATED EQUIPMENT, DAMAGE
TO ASSOCIATED EQUIPMENT, OR COST OF SUBSTITUTE PRODUCTS.

IN NO EVENT, SHALL GE’S LIABILITY TO BUYER FROM THE SALE OF THESE PRODUCTS EXCEED THE PRICE OF THE DEFECTIVE
PRODUCT SOLD AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD.

210575001 Rev. A 1-08

6 of 8

www.geelectrical.com

Содержание WF180

Страница 1: ... Read all instructions before installing or using exhaust fan 2 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer 3 Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on SAVE THESE INSTRUCTIONS IMPORTANT INSTRUCTIONS OPERATING MANUAL accident...

Страница 2: ... have 1 Grill 1 Grill Knob 1 Wiring Compartment and screws 1 Motor 1 Housing 1 Instruction Safety Sheet NOTE This fan is designed to mount between exterior walls 4 1 2 to 9 1 2 in thickness 2 Remove the motor bracket assembly from the fan housing by loosening the two screws which secure the bracket in place Figure 1 3 Slide the inner housing out from the outer housing and set aside in a safe place...

Страница 3: ...oles on the four corners of the housing Seal the flange where the housing meets the wall with caulk Figure 7 SECTION 3 Wiring CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION CAUTION ALLELECTRICALCONNECTIONSMUST BE MADE IN ACCORDANCE WITH LOCAL CODES ORDINANCES OR NATIONAL ELECTRICAL CODE IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING SECURE...

Страница 4: ...crews Rotate the blower wheel by hand to ensure it spins freely Now plug the fan motor into the receptacle Figure 1 2 Install grill by positioning over the inner housing and aligning the center hole on the grill with the hole on the motor bracket Screw one side of the included grill bolt into the hole on the motor bracket and the other side into the grill knob and turn to tighten until the grill i...

Страница 5: ...o receptacle in housing Restore power to unit 1c Wiring is not connected properly 1c Turn off power to unit Check that all wires are connected 1d Motor has stopped operating 1d Replace motor 2 Fan is operating but air moves slower than normal 2 Obstruction in the outer housing 2 Check for any obstructions where the fan exhausts to the outside 3 Fan is operating louder than normal 3a Motor is loose...

Страница 6: ...llation problem contact your dealer or installer You are responsible for providing adequate electrical exhausting and other connecting facilities See the Installation Instructions provided with this product for electrical exhaust and connection details Replacement of house fuses or resetting of circuit breakers Failure of the product if it is used for something other than the intended purpose of m...

Страница 7: ...et 5S2203005 6 1 Spring 5S2203006 7 1 Damper 5S2203007 8 1 Gasket 5S2203008 9 1 Gasket 5S2203009 10 1 Wire Compartment 5S2203010 11 1 Ground Screw 5S2203011 Qty Description Replacement Part 12 1 Wire Compartment Cover 5S2203012 13 1 Polarized Receptacle 5S1999001 14 1 Blade 5S2203013 15 1 Motor 5S2203014 16 1 Motor Bracket 5S2203015 17 4 Mounting Screws 5S2203016 18 1 Blade Spring 5S2203017 19 1 B...

Страница 8: ...210575001 Rev A 1 08 8 of 8 www geelectrical com ...

Отзывы: