VMIACC-5595 Installation Guide
For each of the four dip switches, only position number 1 is used, the other three are
reserved. When the switch is in the “OFF” position, the corresponding direct I/O
signal will read high (1). Likewise, when the switch is in the “ON” position, the
corresponding direct I/O signal will read low (0). Table 1-1 below lists the dip switch
number and description.
To restore the factory default configuration, place switch S4 position 1 to the ON
position and then cycle the power or press the reset button. Each time the unit leaves
reset and senses that switch S4 position 1 is in the ON position, it will restore the unit
settings to the factory default values.
The default values are:
• Password is “password”
• IP address is 10.0.0.1
• IP netmask is 255.255.255.0
• IP gateway is 0.0.0.0
• Serial port baud rate is 9600
• Transmitters are enabled
• All ports operate in the auto bypass mode
• All ports are bypass based on Lost of Signal (LOS) detection
• All ports are set to ‘Dark on Dark’ (off)
CAUTION:
Do not leave switch S4 in the ON position indefinitely. Otherwise, every
time the unit is reset or power cycled the unit will revert to the defaults settings and
your desired configuration will be lost.
Jumper E4 is for factory use only. Leave the jumper shunt of E4 between pins 1 and 2.
Both the serial and the Ethernet port will not operate if the E4 jumper is altered.