Measure

1. Press Measure (18) on the control panel.
The Measurement menu is displayed, showing the
measurement category for the current application.

To change Measurement category:
1. Select the heading in the Measurement menu and

choose another category.

NOTE: This can also be done from the Touch panel.

To perform measurements from a study:
1. Select the study (folder) in the Measurement menu.

NOTE: This can also be done from the Touch panel.

2. Perform the measurement. Follow the instructions

displayed on screen

Caliper

1. Press Caliper (18) on the Control panel and

select the desired measurement tool.

2. Perform

the

measurement.

Follow

the

instructions displayed on screen.

Store

Storing an image:
1. While scanning in any mode, press Freeze.
2. With the trackball, scroll through the cineloop and 

select the required image.

3. Press Store (19)

Storing a cineloop:
1. While scanning, press Store.
2. If desired, select and adjust the cineloop to store 

using the cineloop controls on the touch panel.

3. Press Store (19) to save the cineloop.

NOTE: The system can be configured to perform either

• Retrospective storage: while scanning press Store to 

store
the last elapsed defined number of cycles/seconds.

• Prospective storage: while scanning press Store to 

start storage of the forthcoming defined number of 
cycles/ seconds.
The user can also configure the system to preview the 
cineloop before storage or save the cineloop directly. 
To configure the cineloop

storage go to ‘Global imaging 

settings’ .

Imagination at work

www.gehealthcare.com. Product may not be available in all countries and regions. Contact a GE Healthcare
Representative for more information
Data subject to change.
© 2016 General Electric Company.
GE, the GE Monogram, imagination at work VIVID are trademarks of General Electric Company.
GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC, a General Electric company, doing business as
GE Healthcare. Reproduction in any form is forbidden without prior written permission from GE.

Содержание Vivid S60

Страница 1: ...selection 2D Quick Card Vivid S60 S70 GE Healthcare 1 2 3 4 5 6 7 4D Control Multi D Control Loudspeaker volume ctl Flex Zoom Clear Depth P1 Print capture Freeze 2D Freeze Measure Caliper Store M Mode Color PW CW Tissue Velocity Imaging Trackball Select keys Update Menu Key Trackball Key Upper Key VIVID S70 ONLY ...

Страница 2: ...sor type on the Touch panel 3 With the trackball 9 1 adjust the position of the cursor line 4 Activate the desired mode M Mode 2D Press 2D 8 1 on the control panel to access 2D mode 1 To access M Mode from any other scan mode press MM 8 2 on the control panel 2 Use the trackball 9 1 to position the cursor over the required area of the image 3 Press Freeze 17 4 Use the trackball to scroll through t...

Страница 3: ... an Image store button or an Image cursor To set the function 1 Press Utility Config on the Touch panel 2 Select Imaging Global 4D Control 1 Enter 4D by pressing the 4D button 10 on the control panel The volume acquisition is started 2 Adjust the desired parameters on the touch panel Multi D Control 1 Press Multi D 10 on the control panel NOTE The Bi plane screen is displayed 2 Press Tri plane or ...

Страница 4: ...ignment configuration P1 button configuration NOTE The P1 button on the Control panel can be configured to perform several actions e g Video Print Laser print DICOM storage etc 1 Press Utility Config on the Touch panel 2 Select the Connectivity category and Additional outputs subgroup 3 In Button field select P1 4 Select an output device in the Available output field and press the Right arrow butt...

Страница 5: ...Store 2 If desired select and adjust the cineloop to store using the cineloop controls on the touch panel 3 Press Store 19 to save the cineloop NOTE The system can be configured to perform either Retrospective storage while scanning press Store to store the last elapsed defined number of cycles seconds Prospective storage while scanning press Store to start storage of the forthcoming defined numbe...

Отзывы: