49-2000894 Rev. 3
13
INST
ALLA
TION PREP
ARA
TION
Installation Preparation
POWER SUPPLY
IMPORTANT – (Please read carefully)
WARNING
FOR PERSONAL SAFETY, THIS APPLIANCE
MUST BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with
this appliance. Follow National Electrical Codes or
prevailing local codes and ordinances.
Electrical supply
These vent hoods must be supplied with 120V,
60Hz, and connected to an individual, properly
grounded branch circuit, and protected by a 15 or
20 amp circuit breaker or time delay fuse.
Ŷ
Wiring must be 2 wire with ground.
Ŷ
If the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
Ŷ
Route house wiring as close to the installation
location as possible in the ceiling or wall.
Ŷ
Connect the wiring to the house wiring in
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to
a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.
WARNING
The improper connection of the
equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician
or service representative if you are in doubt whether
the appliance is properly grounded.
PREPARE HOUSE ELECTRICAL
WIRING
The custom cabinet must allow spacing for house
wiring to reach junction box located in diagram
below. If unit is installed over an island, the wiring
must come from ceiling. If power cord is needed,
accessory is available.
9-1/2"
5-3/4"
or
8-3/4"
18" or 24"
Electrical
Area
PREPARE FOR CABINET
INSTALLATION
NOTE:
This bracket must be removed prior to
installation. Remove 2 back (rear) and 2 bottom
screws per illustration bellow.
1. Securely press the damper on top of the exhaust
opening. Check that the damper opens freely.
Attach damper to hood using screws (B) provided.
2. The hood should be centered left to right over
the cooktop.
3. Remove and properly discard the protective
plastic wrapping from the hood.
4. The back surface of the hood must be 1"
minimum from the back wall. The front surface
of the hood must be 3" minimum from the front
custom cabinet panel.
5.
The custom cabinet should provide for
removal of panels to provide access to the
electrical wiring and to the ducting and its
connections to the hood in case of any need
for servicing or other reasons.
1" = 2.5 cm