P/N 55370151 • REV 1.0 • ISS 19OCT10 

 

Description 

The TX-6212-03-1 is a LearnMode wireless smoke detector 
designed for use in a security system with a compatible control 
panel. The detector is designed to comply with 
EN14604:2005/AC:2008. 

The detector has a status LED (Figure 1, item 1), a Silence/Test 
button (Figure 1, item 2), and a built-in sounder for alarm 
indication. 

The status LED flashes every eight seconds to indicate normal 
status (no alarm). When smoke is detected, the status LED 
changes from flashing to on, the built-in sounder is activated, and 
an alarm signal is sent to the control panel. 

The detector sends a supervisory signal to the control panel every 
64 minutes to confirm its status. 

The detector also includes the following features: 

• 

A tamper switch that triggers a tamper signal transmission 
when the detector is removed from its mounting base 

• 

Self-diagnostics to monitor detector sensitivity and 
operational status 

• 

A replaceable optical chamber for easy maintenance 

Installation 

Caution: 

Refer to your control panel documentation for detailed 

information on the corresponding communications, configuration, 
and test requirements. 

Where to install a smoke detector 

Regulations for smoke detector installation vary from region to 
region. For more information, contact your fire service or local 
authority having jurisdiction. 

In addition to local regulations, use the following installation 
guidelines to optimize performance and reduce the chance of 
false alarms from the detector: 

• 

Install ceiling-mounted detectors in the center of a room or 
hallway at least 10 cm (4 in.) from any walls or partitions. 

• 

Install wall-mounted detectors so that the top of the detector 
is 15 to 30 cm (6 to 12 in.) below the ceiling. 

• 

Install all detectors within 30 m (98 ft) of the control panel 

• 

Install detectors away from air conditioners, fans, and any 
other devices that may interfere with smoke entering the 
detector. 

• 

Install detectors on a firm permanent surface away from 
large metallic objects. 

• 

Ensure that the environmental conditions (temperature, 
relative humidity) comply with those indicated in the technical 
specifications. 

Verify communication 

Communication between the detector and the control panel 
should be verified prior to installation. 

To verify communication: 

1.  Put the control panel into the corresponding test mode. 

2.  From the proposed installation location, press and hold the 

detector Silence/Test button for four seconds, and then 

release it. After a short delay the status LED is activated (on) 
and the detector transmits a test alarm signal to the control 
panel. 

3.  Check that the signal is received by the control panel and 

that the signal strength is adequate. If not, relocate the 
detector and perform the test again. 

4.  When adequate communication is confirmed, exit the test 

mode. 

Installation 

To install the detector: 

1.  Remove the detector from the mounting base by turning the 

detector counterclockwise about 15 degrees (Figure 2). 

2.  Slide the battery cover (Figure 3, item 1) away from the 

detector to unsnap it and lift it off. Insert two 3V lithium 
CR123A batteries observing the correct polarity (as indicated 
in the battery compartment). 

Note: the detector cannot be attached correctly to the 
mounting base if the batteries are not installed. 

3.  Remove the red plastic cover from the detector. The detector 

is shipped with the cover for protection against dust on 
construction sites. 

4.  Using the two screws and anchors provided, mount the base 

in the required location. 

5.  To attach the detector to the mounting base, line up the 

alignment tab on the detector (Figure 4, item 1) with the 
alignment arrow on the mounting base (Figure 4, item 2) and 
insert the detector into the base and turn clockwise 
approximately 15 degrees. The detector should snap firmly 
into place. 

6.  Verify that the detector communicates with the control panel 

and test the detector as described in Testing the detector, on 
page 3. 

Operation 

Status LED indications 

The status LED indications are as follows: 

 

LED indication 

Status 

Description 

Flashing 

Normal 

The status LED flashes every eight 
seconds to indicate normal status 

On 

Alarm 

Alarm (smoke has been detected)  

Off 

Fault 

Maintenance is required. Check the 
control panel for further 
information. 

 

The Silence/Test button 

The Silence/Test button operations are as follows: 

 

Operation Description 

Silence the low 
battery alert 

Press the button for one second to silence the 
audible low battery alert (the alert resumes after 
24 hours if the batteries are not replaced). 

Sensitivity and Alarm 
test 

Press the button for four seconds to perform a 
sensitivity test and to send a test alarm signal to 
the control panel 

Содержание TX-6212-03-1

Страница 1: ...GE Security TX 6212 03 1 Wireless Smoke Detector Installation Sheet 1 2 3 4 5 6 2010 UTC Fire Security All rights reserved 1 of 4 P N 55370151 REV 1 0 ISS 19OCT10 ...

Страница 2: ...ified prior to installation To verify communication 1 Put the control panel into the corresponding test mode 2 From the proposed installation location press and hold the detector Silence Test button for four seconds and then release it After a short delay the status LED is activated on and the detector transmits a test alarm signal to the control panel 3 Check that the signal is received by the co...

Страница 3: ... If the error persists replace the detector 4 to 7 The detector is within the normal sensitivity range 8 to 9 The detector is becoming too sensitive Verify that the optical chamber is installed correctly Clean the optical chamber and repeat the test Maintenance Replacing the batteries The detector is powered by two 3V lithium CR123A batteries When batteries are low the detector status LED is off a...

Страница 4: ...on label are the year of manufacture European Union directives 1999 5 EC R TTE directive Hereby UTC Fire Security declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC Manufacturer UTC Fire Security Shanghai UTC Fire Security Electronics 1st Floor No 2 Building No 211 Qinqiao Road Jinqiao Export Processing Zone Pudong New Ar...

Отзывы: