background image

Conforms to the following standards:

RISK OF ELECTRIC SHOCK:

• Turn power OFF before inspection, installation or removal.
• Properly ground Tetra Power Supply enclosure.
• Shut off power at fuse box or circuit breaker before installation.

RISK OF FIRE:

• Follow all NEC and local codes.
• Use only UL approved wire for input/output connections.

Minimum size 18 AWG (0.82 mm

2

)

WARNING!

NOTE:

 The power supply must be mounted in the appropriate (UYMR or UL approved) electrical enclosure. The power 

supply can be mounted horizontally or vertically. It is recommended that at least 2 mountings screws (#8 or #10, M4 or 
M5) be used to mount the power supply. Attach the ground wire (minimum 18 AWG (0.82mm

2

)) to the base of the power 

supply enclosure. The grounding and bonding of the power supply and overall sign shall be done in accordance with 
National Electric Code (NEC) Article 600.

NOTE:

 For CSA approval, a disconnect/toggle switch of appropriate rating needs to be placed within 29.5 feet (9 meters) 

of primary side of the power supply. The minimum rating of the switch must be either 120 or 220 Volts AC. The switch 
must also support twice the amount of input current. 

NOTE:

 When installing power supply, connect to the appropriate sized building breaker or disconnect device, for line and 

neutral connections, in accordance with local, state or country regulations. 

Minimum Typical  Maximum

Input GEXLPS21—Voltage (VAC)

 

108 

120/230 

264

Input GEXLPS21-U—Voltage (VAC)

 

108 

120/230/277 

305

Input Frequency (Hz)

47

    - 

63

Input Current (A) 

0.75 

0.32 

0.26

Output Voltage (VDC) 

11.7 

12.0 

12.3  

 

Output Current (ADC)

0.2

    -

5.0   

Output Power (W)

1.0

    -

65

Environmental Operating Temp. Range

-40°C

+25°C

+60°C

Environmental Humidity (Non-condensing) 

0%

    -

95%

Environmental Storage Temp. Range

-40°C

    -

+85°C

Enclosure Specification 

Dimensions

Damp Location Rated 

9.5 in. x 1.7 in. x 1.2 in. (241 mm x 43.2 mm x 30.5 mm)

NOTE:

 Remote mounting for up to 20 ft. (6.09m) use 14AWG (2.08mm

2

) (GECLSW1), up to 40 ft. (12.20m) use 12AWG (3.31mm

2

),

up to 75 ft. (22.87m) use 10AWG (5.27mm

2

).

 

 

     

Tetra Power White XL

 

 

     

(GEWWXHS3-32K) 3 LEDs/ft (~10 LEDs/m)  

9 / 3 / 0.91 

     

51/17/5.18  

 

 

 

     

(GEWHXHS2-65K, GEWWXH2-32K)) 2 LEDs/ft (~7 LEDs/m) 

9 / 4.5 / 1.37

51 / 25.5 / 7.80

Installation Guide

Power Supply Specifications

6180 Halle Drive • Valley View, Ohio 44125-4635 • USA
P: 216.606.6555 • F: 216.606.6599 • www.led.com • [email protected]

Lumination, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of Lumination, LLC. The GE brand, logo, and ecomagination are trademarks of the General Electric Company. 
© 2008 Lumination, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.

SIGN009-R092308

For customer service & technical support, contact:

1-888-MY-GE-LED

(1.888.694.3533)

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation. This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [ A ] est conforme à la NMB-005 du Canada. 

Load 

Minimum (modules/ft/m) 

Maximum (modules/ft/m)

Tetra XL

6 LEDs/ft (~20 LEDs/m) 

72 / 12 / 3.66 

480 / 80 / 24.38

5 LEDs/ft (~17 LEDs/m)

75 / 15 / 4.57

480 / 96 / 29.26