background image

3

Power Supply Specifications

*Maximum case temperature is 85°C

Performance Data

Min

Typical

Max

Input Voltage (VAC) 

108

120-277

305

Input Frequency (Hz)

-

50/60

-

Input Current (A)

0.35

-

1.1

Output Voltage (VDC)

24

24.5

25.2

Output Current (ADC)

-

-

4.0

Output Power (W)

-

-

96

Environmental Operating Temperature Range

-40°C

+25°C

+60°C*

Environmental Humidity (non-condensing)

0%

-

95%

Environmental Storage Temperature Range

-40°C

-

+85°C

Dimensions

9.5 in. x 1.7 in. x 1.1 in. (241 mm x 43.2 mm x 28 mm)

Chart continued on next page

Remote Mounting Distance

Supports 
Tetra Products

SKUs

Rated Power

Maximum Load 

per Power Supply

18 AWG/

0.82 mm

2

16 AWG/

1.31 mm

2

14 AWG/

2.08 mm

2

12 AWG/

3.31 mm

2

Tetra miniMAX

GEMM2471-W1, GEMM2450-W1,               
GEMM2441-W1,  GEMM2432-W1

0.348W/

module

220 modules/

110 ft. (35.05 m)

20 ft.

(6.1 m)

25 ft.

(7.6 m)

35 ft.

(10.6 m)

40 ft.

(12.1 m)

Tetra MS

GEMS2471-W1, GEMS2450-W1,                 
GEMS2441-W1, GEMS2432-W1

0.228W/

module

340 modules/

85 ft. (25.91 m)

20 ft.

(6.1 m)

25 ft.

(7.6 m)

35 ft.

(10.6 m)

40 ft.

(12.1 m)

Tetra MAX

GEMX2471-W1,  GEMX2450-W1,               
GEMX2441-W1,  GEMX2432-W1

0.62W/

module

130 modules/

87 ft. (26.42 m)

20 ft.

(6.1 m)

25 ft.

(7.6 m)

35 ft.

(10.6 m)

40 ft.

(12.1 m)

Tetra PowerMAX

GEPM2471-W1,  GEPM2450-W1,                   
GEPM2441-W1,  GEPM2432-W1

0.84W/

module

96 modules/

64 ft. (19.5 m)

20 ft.

(6.1 m)

25 ft.

(7.6 m)

35 ft.

(10.6 m)

40 ft.

(12.1 m)

Tetra PowerMAX HO

GEPMH2471-W1CS1,  
GEPMH2450-W1CS1,                   
GEPMH2441-W1CS1,  
GEPMH2432-W1CS1

1.2W/

module

64 modules/

64 ft. (19.5 m)

20 ft.

(6.1 m)

25 ft.

(7.6 m)

35 ft.

(10.6 m)

40 ft.

(12.1 m)

Tetra 
PowerStrip SS

GESS2471-2, GESS2450-2, 
GESS2441-2, GESS2432-2

2.52W/

module

36 modules

20 ft.

(6.1 m)

25 ft.

(7.6 m)

35 ft.

(10.6 m)

40 ft.

(12.1 m)

GESS24H71-1, GESS24H50-1, 
GESS24H41-1, GESS24H32-1

2.95W/

module

30 modules

20 ft.

(6.1 m)

25 ft.

(7.6 m)

35 ft.

(10.6 m)

40 ft.

(12.1 m)

Tetra 
PowerStrip DS

GEDS71-2, GEDS50-2, 
GEDS41-2, GEDS32-2

5.04W/

module

18 modules

20 ft.

(6.1 m)

25 ft.

(7.6 m)

35 ft.

(10.6 m)

40 ft.

(12.1 m)

GEDSH71-2, GEDSH50-2, 
GEDSH41-2, GEDSH32-2

5.9W/

module

16 modules

20 ft.

(6.1 m)

25 ft.

(7.6 m)

35 ft.

(10.6 m)

40 ft.

(12.1 m)

Tetra 
EdgeStrip

GEBI71-2, GEBI50-2, 
GEBI41-2, GEBI32-2

2.52W/

module

36 modules/

36 ft. (10.97 m)

20 ft.

(6.1 m)

25 ft.

(7.6 m)

35 ft.

(10.6 m)

40 ft.

(12.1 m)

GEBIH71-2, GEBIH50-2, 
GEBIH41-2, GEBIH32-2

5.40W/

module

17 modules/

18 ft. (5.49 m)

20 ft.

(6.1 m)

25 ft.

(7.6 m)

35 ft.

(10.6 m)

40 ft.

(12.1 m)

Tetra miniStrip DS

GEBD71-2, GEWWBDP6-50K, 
GEWWBDP6-41K, GEWWBDP6

1.68W/

module

50 modules/

50 ft. (15.23 m)

20 ft.

(6.1 m)

25 ft.

(7.6 m)

35 ft.

(10.6 m)

40 ft.

(12.1 m)

GEBDH71-2, GEBDH50-1, 
GEBDH41-1, GEBDH32-1

1.94W/

module

42 modules/

42 ft. (12.79 m)

20 ft.

(6.1 m)

25 ft.

(7.6 m)

35 ft.

(10.6 m)

40 ft.

(12.1 m)

Содержание Tetra GEPS24-100U-GLX

Страница 1: ...andard ICES 005 Ce DEFR de la classe A est conforme à la NMB 005 du Canada Prepare Electrical Wiring Electrical Requirements Limited to use in dry and damp locations The suitability of rain enclosure shall be determined if intended for wet location The grounding and bonding of the LED Driver shall be done in accordance with National Electric Code NEC Article 600 Follow all National Electric Codes ...

Страница 2: ...deral and local regulations when disposing of neon tubing fluorescent tubes transformers and ballasts 3 Existing Signs Only If removal of the existing lighting equipment eliminates the disconnect switch as required by applicable local state or country electrical codes a new disconnect switch must be installed 4 Existing Signs Only Make sure the removal of lighting equipment does not compromise the...

Страница 3: ...450 W1 GEPM2441 W1 GEPM2432 W1 0 84W module 96 modules 64 ft 19 5 m 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m Tetra PowerMAX HO GEPMH2471 W1CS1 GEPMH2450 W1CS1 GEPMH2441 W1CS1 GEPMH2432 W1CS1 1 2W module 64 modules 64 ft 19 5 m 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m Tetra PowerStrip SS GESS2471 2 GESS2450 2 GESS2441 2 GESS2432 2 2 52W module 36 modules 20 ft 6 1 m 25 ft 7 6 m 35...

Страница 4: ... 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GEF24DHOLED 1 GEF24SGNHOLED 1 GEF24CWHOLED 1 11 5W bar 16 ft 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GEF30DHOLED 1 GEF30SGNHOLED 1 GEF30CWHOLED 1 14 4W bar 16 ft 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GEF36DHOLED 1 GEF36SGNHOLED 1 GEF36CWHOLED 1 17 3W bar 16 ft 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GEF42DHOLED 1 GEF42SGNHO...

Страница 5: ... 35 ft 10 6 m 40 ft 12 1 m GETSPMDS06071A1 GETSPMDS06071B1 11 8 W Stick 7 Sticks 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GETSPMDS06471A1 GETSPMDS06471B1 13 4 W Stick 6 Sticks 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GETSPMDS07271A1 GETSPMDS07271B1 15 2 W Stick 5 Sticks 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GETSPMDS08471A1 GETSPMDS08471B1 16 8 W Stick 5 Sticks 20 ft 6...

Страница 6: ...nd power supply for improper termination s or short circuits Properly terminate or replace the wire connection s Check that connections are the red striped wire of the LED strip to the red wire of the power supply and the white wire of the LED strip to the black or blue wire of the power supply Chart continued Remote Mounting Distance Supports Tetra Products SKUs Rated Power Maximum Load per Power...

Отзывы: