LED Lighting System
imagination at work
Tetra
®
Contour LS
Installation Guide
24
Volt
BEFORE YOU BEGIN
Read these instructions completely and carefully.
RISK OF ELECTRIC SHOCK:
• Disconnect power at fuse box or circuit breaker before
servicing or installing product.
• Properly ground Tetra
®
power supply.
RISK OF FIRE:
• Use only Tetra
®
supply wire to make connection from
Tetra
®
power supply to Tetra
®
LED strip.
• Use only approved wire for input/output connection.
Minimum size 18 AWG (0.82mm
2
)
• Follow all local codes.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant
l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre l’alimentation électrique Tetra
®
.
RISQUES D’INCENDIE
• N’utilisez que le fil d’approvisionnement Tetra
®
pour faire la connexion entre
l’alimentation Tetra
®
et la bande DEL Tetra
®
.
• N’utilisez que des fils approuvés pour les entrées/sorties de connexion. Taille
minimum 18 AWG (0.82mm
2
).
• Respectez tous les codes locaux.
WARNING/AVERTISSEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Components and Tools required:
UL approved 18 AWG (0.82mm
2
)
supply wire
End Caps
Weather Boxes
Light Guide Mounting Clips
12
13
11
10
9
8
1
2
3
4
5
6
7
22 AWG (0.33mm
2
) tie-wire
#6, #8 or #10 (M2, M3 or M4) self drilling pan
headed screws
UL approved twist‑on wire connectors fitting
both 18 and 20 AWG wire (0.82mm
2
, 0.52mm
2
)
Tetra
®
24 Volt Power Supply
Tetra
®
Contour LS
Cordless drill
Tape measure
Electrical grade silicone (suggested
manufacturers page 2)
Wire stripper/cutter
1
2
3
4
5
6
7
8
10
12
13
11
(GEXNLBL-1, GEXNLGL-1, GEXNLRD-1, GEXNL65-1, GEXNL32-1)
GE
Lighting
Save These Instructions
Use only in the manner intended by
the manufacturer. If you have any
questions, contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
• Limited to use in dry and damp locations.
• The grounding and bonding of the LED Driver shall be done in accordance with
National Electric Code (NEC) Article 600.
• Follow all National Electric Codes (NEC) and local codes.
• These products are only suitable for connection to a circuit from a Class 2 power
source. These products have not been evaluated for use when connected to a power
source that does not comply with Class 2 voltage and energy limited supplies.
Tc=80°C
(–)
(+)
9
8 feet (2.44m)