24

Volt

BEFORE YOU BEGIN

Read these instructions completely and carefully.

RISK OF ELECTRIC SHOCK:

• Disconnect power at fuse box or circuit breaker before  

  servicing or installing product.

• Properly ground Tetra

®

 power supply.

RISK OF FIRE:

• Use only Tetra

®

 supply wire to make connection from  

 Tetra

®

 power supply to Tetra

®

 LED strip.

• Use only approved wire for input/output connection. 

  Minimum size 18 AWG (0.82mm

2

)

• Follow all local codes.

RISQUES DE DÉCHARGES ÉLECTRIQUES

• Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant  

  l’entretien ou l’installation du produit.

• Assurez-vous de correctement mettre à terre l’alimentation électrique Tetra

®

.

RISQUES D’INCENDIE

• N’utilisez que le fil d’approvisionnement Tetra

®

 pour faire la connexion entre  

  l’alimentation Tetra

®

 et la bande DEL Tetra

®

.

• N’utilisez que des fils approuvés pour les entrées/sorties de connexion. Taille  

  minimum 18 AWG (0.82mm

2

).

• Respectez tous les codes locaux.

WARNING/AVERTISSEMENT

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful 

interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are 

designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment 

generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful 

interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be 

required to correct the interference at his own expense.

Components and Tools required:

UL approved 18 AWG (0.82mm

2

supply wire 
End Caps 
Weather Boxes
Light Guide Mounting Clips

12

13

11

10

9

8

1

2
3
4

5
6

7

22 AWG (0.33mm

2

) tie-wire

#6, #8 or #10 (M2, M3 or M4) self drilling pan 

headed screws
UL approved twist‑on wire connectors fitting 

both 18 and 20 AWG wire (0.82mm

2

, 0.52mm

2

)

Tetra

®

 24 Volt Power Supply

Tetra

®

 Contour LS      

Cordless drill
Tape measure
Electrical grade silicone (suggested 

manufacturers page 2)
Wire stripper/cutter

1

2

3

4

5

6

7

8

10

12

13

11

(GEXNLBL-1, GEXNLGL-1, GEXNLRD-1, GEXNL65-1, GEXNL32-1)

GE

Lighting

Save These Instructions

Use only in the manner intended by 

the manufacturer. If you have any 

questions, contact the manufacturer.

Prepare Electrical Wiring

Electrical Requirements

• Limited to use in dry and damp locations.

• The grounding and bonding of the LED Driver shall be done in accordance with  

 

  National Electric Code (NEC)  Article 600.

• Follow all National Electric Codes (NEC) and local codes.

• These products are only suitable for connection to a circuit from a Class 2 power    

  source. These products have not been evaluated for use when connected to a power  

  source that does not comply with Class 2 voltage and energy limited supplies.

Tc=80°C

(–)

(+)

9

8 feet (2.44m)

Содержание Tetra Contour LS Series

Страница 1: ...le protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which cas...

Страница 2: ... 1 White 8 inches 203 mm GEXNL32 1 Warm White 8 inches 203 mm Space mounting clips 18 inches 457mm apart Attaching Contour Sections 2 1 Starting from one end attach the Tetra Contour LS to the mounting clips Secure light guide by twisting tie wire around the mounting clip and light guide NOTE Wires can be concealed by tucking wires between mounting clips and Tetra Contour LS system Install one mou...

Страница 3: ...or removal 3 Using twist on wire connectors connect the white wire with red stripe from the LED strip to the red wire of the power supply Connect the white wire from the LED strip to the black or blue wire of the power supply NOTE Grounding and bonding must be done in accordance with National Electrical Code Article 600 See power supply instructions White with red stripe Red White Black or blue To...

Страница 4: ... AWG 2 08 mm2 Supply Wire 12 AWG 3 31 mm2 Supply Wire 20W Power Supply 20 ft 6 1 m 80W Power Supply 20 ft 6 1 m 30 ft 9 1 m 50 ft 15 2 m 86 ft 26 1 m 100W Power Supply 20 ft 6 1 m 30 ft 9 1 m 50 ft 15 2 m 86 ft 26 1 m 180W Power Supply 20 ft 6 1 m 30 ft 9 1 m 50 ft 15 2 m 86 ft 26 1 m Symptom Solution All LEDs are OFF Check AC input connection and or check circuit breaker Check wire connection s a...

Отзывы: