GE Multilin
T60 Transformer Protection System
E-1
APPENDIX E
E.1 IEC 60870-5-104 PROTOCOL
E
APPENDIX E IEC 60870-5-104 COMMS.E.1IEC 60870-5-104 PROTOCOL
E.1.1 INTEROPERABILITY DOCUMENT
This document is adapted from the IEC 60870-5-104 standard. For this section the boxes indicate the following:
– used
in standard direction;
– not used;
– cannot be selected in IEC 60870-5-104 standard.
1.
SYSTEM OR DEVICE:
System Definition
Controlling Station Definition (Master)
Controlled Station Definition (Slave)
2.
NETWORK CONFIGURATION:
Point-to-Point
Multipoint
Multiple Point-to-Point
Multipoint Star
3.
PHYSICAL LAYER
Transmission Speed (control direction):
Transmission Speed (monitor direction):
4.
LINK LAYER
Unbalanced Interchange
Circuit V.24/V.28 Standard:
Unbalanced Interchange
Circuit V.24/V.28 Recommended
if >1200 bits/s:
Balanced Interchange Circuit
X.24/X.27:
100 bits/sec.
200 bits/sec.
300 bits/sec.
600 bits/sec.
1200 bits/sec.
2400 bits/sec.
4800 bits/sec.
9600 bits/sec.
2400 bits/sec.
4800 bits/sec.
9600 bits/sec.
19200 bits/sec.
38400 bits/sec.
56000 bits/sec.
64000 bits/sec.
Unbalanced Interchange
Circuit V.24/V.28 Standard:
Unbalanced Interchange
Circuit V.24/V.28 Recommended
if >1200 bits/s:
Balanced Interchange Circuit
X.24/X.27:
100 bits/sec.
200 bits/sec.
300 bits/sec.
600 bits/sec.
1200 bits/sec.
2400 bits/sec.
4800 bits/sec.
9600 bits/sec.
2400 bits/sec.
4800 bits/sec.
9600 bits/sec.
19200 bits/sec.
38400 bits/sec.
56000 bits/sec.
64000 bits/sec.
Link Transmission Procedure:
Address Field of the Link:
Balanced Transmission
Unbalanced Transmission
Not Present (Balanced Transmission Only)
One Octet
Two Octets
Structured
Unstructured
Frame Length (maximum length, number of octets): Not selectable in companion IEC 60870-5-104 standard
Содержание T60
Страница 6: ...vi T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Страница 14: ...xiv T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Страница 34: ...1 20 T60 Transformer Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 118: ...3 48 T60 Transformer Protection System GE Multilin 3 3 DIRECT INPUT OUTPUT COMMUNICATIONS 3 HARDWARE 3 ...
Страница 146: ...4 28 T60 Transformer Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 490: ...5 344 T60 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 522: ...6 32 T60 Transformer Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 536: ...7 14 T60 Transformer Protection System GE Multilin 7 1 COMMANDS 7 COMMANDS AND TARGETS 7 ...
Страница 538: ...8 2 T60 Transformer Protection System GE Multilin 8 1 DIRECTIONAL PRINCIPLE 8 THEORY OF OPERATION 8 ...
Страница 568: ...10 12 T60 Transformer Protection System GE Multilin 10 6 DISPOSAL 10 MAINTENANCE 10 ...
Страница 596: ...A 28 T60 Transformer Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 716: ...B 120 T60 Transformer Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Страница 762: ...E 10 T60 Transformer Protection System GE Multilin E 1 IEC 60870 5 104 PROTOCOL APPENDIX E E ...
Страница 774: ...F 12 T60 Transformer Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Страница 785: ...GE Multilin T60 Transformer Protection System H 9 APPENDIX H H 2 ABBREVIATIONS H Z Impedance Zone ...