GE Reason Switches
Chapter 9
– Installation
266
REASON SWITCHES-TM-EN-3
3
Power Connections
Reason Switches contain a double-redundant power supply source.
The protective grounding connector symbol shall be electrically connected to the
metallic mass of the rack cabinet in which the switch shall be installed.
All power connections should use insulated flameproof flexible cable (BWF type) with
a 1.5 mm² cross section, 70 °C (158 °F) thermal class, and 750 V insulation voltages.
Figure 90: T1000 (left) and S2020/S2024G (right) Power Supply Connector
Terminal Number
Description
Use
1
+/L
+/L is connected to the positive cable (+) if the
power source is DC, or to the phase cable if the
power source is AC.
2
-/N
-/N is connected to the negative cable (-) if the
Power source is DC, or to the neutral cable if the
power source is DC.
3
Is connected to the grounding safety cable
(EARTH) both for AC and DC sources.
4
+/L
+/L is connected to the positive cable (+) if the
power source is DC, or to the phase cable if the
power source is AC. (Available only for equipment
that provide a redundant source)
5
-/N
-/N is connected to the negative cable (-) if the
power source is DC, or to the neutral cable if the
power source is DC. (Available only for equipment
that provide redundant source)
Содержание T1000
Страница 2: ......
Страница 11: ...Figure 97 T1000 dimensions 298 Figure 98 S2020 and S2024G dimensions 299...
Страница 12: ......
Страница 41: ...Chapter 3 Hardware Design GE Reason Switches REASON SWITCHES TM EN 3 41 Figure 4 S2024G Switch...
Страница 103: ...GE Reason Switches Chapter 4 Functions REASON SWITCHES TM EN 3 103 Figure 64 Data Monitor Flow Network...
Страница 256: ......
Страница 274: ......