Installation Instructions
TEST FOR LEAKS
Never use an open flame to test for gas leaks.
Check all connections for leaks with soapy solution or
equivalent.
Apply a soap solution. The leak test solution must not
contain ammonia, which could cause damage to the
brass fittings.
If leaks are found, close the valve, retighten the joint
and repeat the soap test.
ELECTRICAL CONNECTION
INFORMATION FOR GAS DRYERS
(cont.)
ELECTRICAL CONNECTION
INFORMATION FOR GAS DRYERS
Plug into a grounded 3 prong outlet.
DO NOT
remove ground prong.
DO NOT
use an adapter.
DO NOT
use an extension cord.
Failure to do so can result in death, fire or
electrical shock.
• Circuit – Individual properly polarized and grounded
15 or 20 amp circuit breaker or time-delay fuse.
• Power Supply – 2-wire plus ground, 120 Volt, single
phase, 60 Hz, alternating current.
• Outlet Receptacle –
Properly grounded
3-prong receptacle
to be located so the
power cord is accessible
when the dryer is in an
installed position. If a
2-prong receptacle is present, it is the owner’s
responsibility to have a licensed electrician replace
it with a properly grounded 3-prong grounding type
receptacle.
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event
of a malfunction or breakdown, grounding will
reduce the risk of electric shock by providing a
path of least resistance for electric current. This
appliance uses a cord having an equipment-
grounding conductor and a grounding plug.
The plug must be plugged into an appropriate
outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
Improper connection of the
equipment-grounding conductor
can result in a risk of electric shock. Check with a
qualified electrician, or service representative or
personnel, if you are in doubt as to whether the
appliance is properly grounded.
DO NOT
modify
the plug on the power supply cord. If it will not
fit the outlet, have a proper outlet installed by a
qualified electrician.
SAVE THESE INSTRUCTIONS
• Appliance must be electrically grounded in
accordance with local codes and ordinances, or in
the absence of local codes, with the latest edition of
the NATIONAL ELECTRICAL CODE, ANSI/NFPA
NO. 70 or CANADIAN ELECTRICAL CODE, CSA
C22.1. Check with a licensed electrician if you are
not sure that the dryer is properly grounded.
Open Gas
Valve
Ensure proper
ground exists
before use.
- Electrical Shock Hazard
WARNING
WARNING