Catalog Number: RSP12

RSP12

RED

BLACK

WHITE

RED

BLACK

WHITE

RED

BLACK

WHITE

RED

BLACK

WHITE

RED

BLACK

WHITE

RED

BLACK

WHITE

RED

BLACK

WHITE

RED

BLACK

WHITE

RED

BLACK

WHITE

RED

BLACK

WHITE

RED

BLACK

WHITE

RED

BLACK

WHITE

MAINTAINED

ISOLATED

CONTACT

2-WIRE

MOMENTARY

PUSH BUTTON

STANDARD

3-WIRE

MOMENTARY

STANDARD

3-WIRE

MAINTAINED

20/2 AWG 1000 FT. MAX.

20/2 AWG 1000 FT. MAX.

20/3 AWG 1000 FT. MAX.

20/3 AWG 1000 FT. MAX.

JUMP RED TO BLACK

JUMP BLACK TO WHITE

12-RELAY 
LIGHTING
AUTOMATION
PANEL

24-RELAY LIGHTING
AUTOMATION PANEL

48-RELAY LIGHTING
AUTOMATION PANEL

RSP12

RED

BLACK

BLUE

ON TLC PANEL

MOTHERBOARD

YELLOW

RED

BLACK

WHITE

1

RRxP RELAY

LOAD

CIRCUIT

20/2 AWG

24VRECT ACC

BLUE    WHITE

24V

RECT

BLUE

PILOT

COMMON

YELLOW

24VAC     COM

2

4V

RECT

BLUE

ON TLC PANEL

MOTHERBOARD

18/2 AWG

RSP12

INSTALLATION

CAUTION: The power supply must be OFF when
inserting or removing components. These instructions
assume the panel has a standard cover which exposes

both line-voltage and low-voltage sections. The line-
voltage sections must be covered to avoid exposure to
live high-voltage wiring.

There are two recommended ways to install the RSP12
Remote Control Smart Sweeper — in a Lighting
Automation Panel (LAP) or in an Accessory Cabinet near
a Lighting Automation Panel

Installation in a Lighting Automation Panel

A complete LAP assembly includes the following TLC
components:

Tub

RTUB12, -24 or -48

Cover

RCOV12xx, -24xxx or -48xxx

Interior

RINTER0012RC, -0024RC or -0048RC*

Power Supply

RPWRxxx

Relays

RR7P or RR9P

* RINTER0012RC and -0024RC accept one RSP12, RINTER0048RC accepts one or two

Details for assembling a complete Lighting Automation
Panel are outlined separately in the RINTER installation
instructions. Once the panel is assembled and relays are
connected to the motherboard, the RSP12 may be
installed.

Basic Installation Steps

1. Mount the RSP12(s) on the panel accessory bracket.
2. Wire 24V rectified power from the panel motherboard

to the blue and white power input tabs on the RSP12.

3. Wire red and black connections for each relay from

the panel motherboard to relay outputs on the RSP12.

4. Wire any 2- or 3-wire switch to  the individual switch

inputs and/or the Master switch input on the RSP12
(not on the panel motherboard).

5. Select additional control functions.

Installation in an Accessory Cabinet near the LAP

Accessory cabinets with covers include:

RBS1

Accepts one (1) RSP12

RBS2

Accepts two (2) RSP12s

Mount the RSP12 in the accessory cabinet and wire the
same as above.

2.
WIRE
24 VOLT
RECTIFIED
POWER

4. WIRE ANY 2- OR 3-WIRE SWITCHES

1. MOUNT RSP12 IN PANEL

3.
WIRE
RELAYS

Содержание RSP12

Страница 1: ...NTROLS COPYRIGHT 1995 437D687 REV 0 RED BLACK BLUE R L Y 2 RED BLACK BLUE R L Y 3 RED BLACK BLUE R L Y 4 RED BLACK BLUE R L Y 5 RED BLACK BLUE R L Y 6 RED BLACK BLUE R L Y 7 RED BLACK BLUE R L Y 8 RED BLACK BLUE R L Y 9 RED BLACK BLUE R L Y 1 0 RED BLACK BLUE R L Y 1 1 RED BLACK BLUE R L Y 1 2 ASM 437D688G RED BLACK WARN YES NO TIME DELAY AUTO ON YES NO BLUE S W T 1 2 RED BLACK WHITE S W T 1 1 RED...

Страница 2: ...ation Panel motherboard Master Switch Input Master ON OFF control for all connected relays 12 Individual Relay Outputs Connect up to 3 relays wired in parallel per output Auto On Function Can turn on all lights automatically at the start of normal working hours Time Delay Function After hours any individual switch over ride will automatically be turned off if time delay is set from 15 minutes to 2...

Страница 3: ...tion Panel LAP or in an Accessory Cabinet near a Lighting Automation Panel Installation in a Lighting Automation Panel A complete LAP assembly includes the following TLC components Tub RTUB12 24 or 48 Cover RCOV12xx 24xxx or 48xxx Interior RINTER0012RC 0024RC or 0048RC Power Supply RPWRxxx Relays RR7P or RR9P RINTER0012RC and 0024RC accept one RSP12 RINTER0048RC accepts one or two Details for asse...

Страница 4: ...after hours OPEN contact Properly connecting and scheduling the Occupied contact determines when other functions will be enabled Time Delay If the Time Delay function is set when an occupant turns on a switch after hours Occupied contact OPEN the RSP12 will turn off the lights again after a predetermined amount of time Each occupant override will have its own time delay Set the Time Delay dial as ...

Отзывы: