PERFORMANCE DATA SHEET

MODEL: GE RPWFE 

Use Replacement Cartridge RPWFE.  
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the 
permissible limit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53. System tested and certified by NSF 
International against NSF/ANSI Standard 42 and Standard 53 for the reduction of substances listed below. 

THE FOLLOWING PHARMACEUTICAL REDUCTION CLAIMS HAVE NOT BEEN CERTIFIED BY NSF INTERNATIONAL. CLAIMS 

TESTED AND VERIFIED BY INDEPENDENT LABORATORY:

SUBSTANCE  
REDUCTION

AVERAGE  

INFLUENT

NSF SPECIFIED 

 CHALLENGE  

CONCENTRATION

AVG %  

REDUCTION

AVERAGE PRODUCT 

WATER  

CONCENTRATION

MAX PERMISSIBLE  

PRODUCT WATER  
CONCENTRATION

NSF  

TEST REPORT

Atenolol

1088 ng/L

N/A

99.5%

5.0 ng/L

N/A

J-00103221

Fluoxetine

845 ng/L

N/A

99.4%

5.0 ng/L

N/A

J-00103221

Ibuprofen

898 ng/L

N/A

98.8%

9.9 ng/L

N/A

J-00103726

Progesterone

945 ng/L

N/A

99.4%

5.5 ng/L

N/A

J-00103727

Trimethoprim

403 ng/L

N/A

99.5%

2.0 ng/L

N/A

J-00103221

It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.  
See Installation Manual for Warranty information.

APPLICATION GUIDELINES/WATER SUPPLY PARAMETERS

Service Flow

0.5 gpm  (1.89 lpm)

Water Supply

Potable Water

Water Pressure

25-120 psi (172– 827 kPa)

Water Temperature

33º F - 100º F (0.6º C - 38º C)

NOTE:

 

While the testing was performed under standard laboratory conditions, 

actual performance may vary. 
Replacement Cartridge: RPWFE. For estimated costs of replacement elements  
please call 1-800-626-2002 or visit our website at www.geapplianceparts.com.

       WARNING

To reduce the risk associated with ingestion of contaminants:

›;fefklj\n`k_nXk\ik_Xk`jd`ZifY`fcf^`ZXccplejX]\fif]lebefne

quality without adequate disinfection before and after the system.

 Systems 

certified for cyst reduction may be used on disinfected water that may contain 
filterable cysts. EPA Establishment Number 070595-MEX-001.

NOTICE

To reduce the risk of water leakage or flooding, and to ensure optimal filter 
performance: 

›I\X[Xe[]fccfn

 

use instructions before installation and use of this system.

›@ejkXccXk`feXe[lj\

MUST 

comply with all state and local plumbing codes.

›;fefk

 install if water pressure exceeds 120 psi (827 kPa). If your water 

pressure exceeds 80 psi, you 

must

 install a pressure-limiting valve. Contact a 

plumbing professional if you are uncertain how to check your water pressure. 

›;fefk

 install where water hammer conditions may occur. If water hammer 

conditions exist you 

must

 install a water hammer arrester. Contact a 

plumbing professional if you are uncertain how to check for this condition.

›;fefk

 

install on hot water supply lines. The maximum operating water 

temperature of this filter system is 100º F (38º C).

›Gifk\ZkÓck\i]ifd]i\\q`e^%

 

Drain filter when temperatures drop  

below 33ºF (0.6ºC).

›:_Xe^\k_\[`jgfjXYc\Óck\iZXiki`[^\\m\ipj`odfek_jfijffe\i`]pfl

observe a noticeable reduction in water flow rate.

›=X`cli\kfi\gcXZ\k_\[`jgfjXYc\Óck\iZXiki`[^\Xki\Zfdd\e[\[`ek\imXcj

may lead to reduced filter performance and cracks in the filter housing, 
causing water leakage or flooding.

CAPACITY 170 GALLONS (643.5 LITERS).   CONTAMINANT REDUCTION DETERMINED BY NSF TESTING.

SUBSTANCE TESTED  
FOR REDUCTION

AVERAGE  

INFLUENT

NSF SPECIFIED 

 CHALLENGE  

CONCENTRATION

AVG %  

REDUCTION

AVERAGE  

PRODUCT WATER  
CONCENTRATION

MAX PERMISSIBLE 

PRODUCT WATER 
CONCENTRATION

NSF  

REDUCTION 

REQUIREMENTS

NSF  

TEST REPORT

Chlorine Taste and 
Odor

2.0 mg/L

2.0 mg/L ± 10%

97.4%

0.05 mg/L

N/A

*

50%

J-00102044

Nominal Particulate  
Class I, , 

*

0.5 to < 1.0 

μ

m 7,633,333 pts/mL At least 10,000 particles/mL

99.0%

71,850 pts/ml

N/A

*

85%

J-00106249

Asbestos

109 MFL

10

7

 to 10

8

 fibers/L; fibers 

greater than 10

μ

m in length

99.99%

<1 MFL

N/A

*

99%

J-00102069

Atrazine

0.009 mg/L

0.009 mg/L ± 10% 

94.4%

0.0005 mg/L

0.003 mg/L

N/A

J-00102058 

Benzene

0.016 mg/L

0.015 mg/L ± 10%

96.4%

0.001 mg/L

0.005 mg/L

N/A

J-00102065

Carbofuran

0.08 mg/L

0.08 mg/L ± 10%

98.8%

0.001 mg/L

0.04 mg/L

N/A

J-00102059

Cyst*

104,750 cysts/L

Minimum 50,000 cysts/L

99.99%

3 cyst/L

N/A

*

99.95%

J-00102057

Lead pH @6.5 

0.140 mg/L

0.15 mg/L ± 10%

99.3%

0.001 mg/L

0.010 mg/L

N/A

J-00102052

Lead pH @8.5

0.158 mg/L

0.15 mg/L ± 10%

98.3%

0.002 mg/L

0.010 mg/L

N/A

J-00102053

Mercury @ pH 6.5

0.006 mg/L

0.006 mg/L ± 10%

91%

0.0003 mg/L

0.002 mg/L

N/A

J-00102054

Mercury @ pH 8.5

0.006 mg/L

0.006 mg/L ± 10%

88.3%%

0.0007 mg/L

0.002 mg/L

N/A

J-00104087

Lindane

0.002 mg/L

0.002 mg/L ± 10%

99%

0.00002 mg/L

0.0002 mg/L

N/A

J-00102063

P-Dichlorobenzene

0.222 mg/L

0.225 mg/L ± 10%

99.8%

0.0005 mg/L

0.075 mg/L

N/A

J-00102067

Toxaphene

0.015 mg/L

0.015 mg/L ± 10%

93.5%

0.001 mg/L

0.003 mg/L

N/A

J-00102061

2, 4-D Reduction

0.218 mg/L

0.210 mg/L±10%

99.9%

0.0001 mg/L

0.07 mg/L

N/A

J-00102064

VOC

0.278 mg/L

0.300 mg/L ± 10%

97.7%

0.0015 mg/L

N/A

*

95%

J-00102070

*Based on the use of Cryptosporidium parvum oocysts.

REPLACEMENT 

 ELEMENT

Tested and certified by NSF International 

against NSF/ANSI Standard 42 and Standard 

53 in model GE RPWF and GE RPWFE for 

the reduction of the claims specified on the 

performance data sheet.

RPWFE

34-8715-2704-9

239D4126P003 REV 4   