Performance RHM 80

Max Flow Rate Qmax = 8000 kg/min (17637 lb/min) and Qnom (*) = 5000 kg/min (11023 lb/min) 

3

Standard Models

Flow Rate

Uncertainty

kg/min

lb/min

in % of reading

8000

17637

0.20

4000

8818

0.20

1000

2205

0.20

400

882

0.20

200

441

0.50

Goldline Models (**) - selected sensors

Flow Rate

Uncertainty

kg/min

lb/min

in % of reading

6000

13228

0.15

4500

9921

0.15

3000

6614

0.15

1500

3307

0.15

600

1323

0.15

Low Flow Models (**) - selected sensors

Flow Rate

Uncertainty

kg/min

lb/min

in % of reading

8000

17637

0.20

2000

4409

0.20

400

882

0.20

200

441

0.50

130

287

0.60

Uncertainty %                                                                             DP (bar)

Flow Rate kg/min

Uncertainty %                                                                             DP (bar)

Flow Rate kg/min

Uncertainty %                                                                             DP (bar)

Repeatability  

Better ± 0.1% of rate,  

 

Goldline 0.05%   

Density  

Down to 0.5% uncertainty 

Temperature  

Better ± 1°C 

 

(*) Nominal flow Qnom refers to roughly 8 - 10 m/s 

(26 - 33 ft/s) velocity in measuring loops for best 

performance. 

(**) Selected sensors are only available in combination 

with temperature options T1, TA, standard material and 

pressure range. 

Flow Rate kg/min

•  Uncertainty of reading (incl. zero drift) indications 

refer to reference conditions H

2

O, 18-24°C (66 - 76°F), 

1 - 3 bar (15 – 45 psi) and installation according to 

field manual.   

 

 

 

• 

Pressure drop indications refer to H

2

O, with 

measuring loops type P1.

• 

For calibration to customer range and / or with 

improved uncertainty, please consult your local 

agent. 

Содержание RHM 80

Страница 1: ...b min with temperatures in excess of 280 C and pressures up to 198 bar This large sized model is also appropriate for tough application conditions manufactured by GE s Rheonik mass flowmeter experts Minimal flows as low as 130 kg min Customization possible Hazardous Area Approvals ATEX CSA Advantages High flow rates for fast filling in combination with high operating pressure Torsion oscillator de...

Страница 2: ...nsmitter approx 550 kg 1213 lb Finish type of our ANSI flanges corresponds to SF AARH 125 up to 250 μin Ra 3 2 up to 6 3 μm For customization with regard to face to face length and special fittings please consult your local agent 2 Process Connection Face to face length L Order Code mm in Standard Flange DIN DN150 PN16 900 35 43 D1 Flange DIN DN150 PN40 900 35 43 D2 Flange ANSI 6 150 RF SF 900 35 ...

Страница 3: ...ainty DP bar Flow Rate kg min Uncertainty DP bar Flow Rate kg min Uncertainty DP bar Repeatability Better 0 1 of rate Goldline 0 05 Density Down to 0 5 uncertainty Temperature Better 1 C Nominal flow Qnom refers to roughly 8 10 m s 26 33 ft s velocity in measuring loops for best performance Selected sensors are only available in combination with temperature options T1 TA standard material and pres...

Страница 4: ...ge DIN DN150 PN16 Form C EN 1092 1 Form B1 D2 Flange DIN DN150 PN40 Form C EN 1092 1 Form B1 A1 Flange ANSI 6 150 RF SF A2 Flange ANSI 6 300 RF SF A3 Flange ANSI 3 600 RF SF Others on request RHM 80 Basic Order Code RHM 80 General Specifications RHM 80 Temperature Range NT Models from 20 to 120 C 4 to 248 F ET Models from 45 to 120 C 49 to 248 F ET2 Models from 45 to 210 C 49 to 410 F ET1 Models f...

Отзывы: