Pressure Rating RHM 80

The maximum pressure (pmax) of a sensor is determined by its weakest part. The weakest part can be the measuring 

loops (pmax indicated below) or the selected flanges / fittings (for pmax please see respective standard). For optional 

materials like Alloy C22, wall thickness of measuring loops may change by +/- 10%.

Pmax of P1 measuring pipes 
M1 standard material - 1.4571 (316Ti) 
OD x WT 88.9 x 4.05 mm (3.5 x 0.159 in)

bar

°C

psi

°F

104

50

1508

122

93

120

1349

248

80

210

1160

410

67

350

972

662

pmax of P2 measuring loops 
M1 standard material - 1.4571 (316Ti) 
OD x WT 88.9 x 6.3 mm (3.5 x 0.248 in)

bar

°C

psi

°F

165

50

2393

122

148

120

2147

248

127

210

1842

410

107

350

1552

662

General Dimensions RHM 80 

PF0 

(parallel, sealless/welded construction with flange 

connection)

A2 = 1320 mm (51.97 in)  

 

H1 = 1505 mm (59.25 in)  

Terminal box (without cable gland) 125 x 80 x 58 mm (4.92 x 3.15 x 2.28 in)

B2 = 403 mm (15.87 in)   

 

H2 = 1775 mm (69.88 in)  

W =  150 mm (5.91 in)

Weight with 150# flanges: approx. 380 kg (838 lb) 

 

 

 

 

 

Shipping in wooden crate as per ISPM 15, approx. 220 x 160 x 90 cm (87 x 63 x 36 in), gross weight with 150# flanges and RHE 08 transmitter approx. 550 kg (1213 lb) 

      

Finish type of our ANSI flanges corresponds to SF (AARH 125 up to 250 μin, Ra 3.2 up to 6.3 μm)   

 

 

 

 

      

For customization with regard to face to face length and special fittings, please consult your local agent 

2

Process Connection 

Face to face length (L)  Order Code

mm

in

Standard

Flange DIN DN150/PN16

900

35.43

D1

Flange DIN  DN150/PN40

900

35.43

D2

Flange ANSI 6" 150# RF/SF 

900

35.43

A1

Flange ANSI 6" 300# RF/SF 

900

35.43

A2

Flange ANSI 6'' 600# RF/SF (*)

900

35.43

A3

Optional

Flange DIN DN150/PN100 (*)

900

35.43

D3

Flange DIN DN200/PN16

900

35.43

D8

Flange ANSI 6" 900# RF/SF (*)

900

35.43

A7

Flange ANSI 6" 900# RTJ (*)

900

35.43

R1

Flange ANSI 6" 1500# RF/SF (*)

900

35.43

A9

Flange ANSI 6" 1500# RTJ (*)

900

35.43

R2

Flange ANSI 6" 2500# RTJ (*)

900

35.43

R3

Flange ANSI 8" 300# RF/SF 

900

35.43

A6

Flange ANSI 10" 300# RF/SF 

900

35.43

A8

Flange JIS RF 10k 150A (6")

900

35.43

J1

Flange JIS RF 20k 150A (6")

900

35.43

J2

pmax of P1 measuring loops 
M3 optional material - 2.4602 (Alloy C22) 
OD x WT 88.9 x 4 mm (3.5 x 0.157 in)

bar

°C

psi

°F

141

50

2045

122

125

120

1813

248

106

210

1537

410

89

350

1291

662

pmax of P1 measuring loops   

 

 

62 optional material - 1.4462 (Duplex) 

 

OD x WT 88.9 x 4.05 mm (3.5 x 0.159 in)

bar

°C

psi

°F

198

50

2872

122

174

120

2524

248

152

210

2205

410

* Flange reduces the maximum allowable tube pressure by a factor of 0.73.

Содержание RHM 80

Страница 1: ...b min with temperatures in excess of 280 C and pressures up to 198 bar This large sized model is also appropriate for tough application conditions manufactured by GE s Rheonik mass flowmeter experts Minimal flows as low as 130 kg min Customization possible Hazardous Area Approvals ATEX CSA Advantages High flow rates for fast filling in combination with high operating pressure Torsion oscillator de...

Страница 2: ...nsmitter approx 550 kg 1213 lb Finish type of our ANSI flanges corresponds to SF AARH 125 up to 250 μin Ra 3 2 up to 6 3 μm For customization with regard to face to face length and special fittings please consult your local agent 2 Process Connection Face to face length L Order Code mm in Standard Flange DIN DN150 PN16 900 35 43 D1 Flange DIN DN150 PN40 900 35 43 D2 Flange ANSI 6 150 RF SF 900 35 ...

Страница 3: ...ainty DP bar Flow Rate kg min Uncertainty DP bar Flow Rate kg min Uncertainty DP bar Repeatability Better 0 1 of rate Goldline 0 05 Density Down to 0 5 uncertainty Temperature Better 1 C Nominal flow Qnom refers to roughly 8 10 m s 26 33 ft s velocity in measuring loops for best performance Selected sensors are only available in combination with temperature options T1 TA standard material and pres...

Страница 4: ...ge DIN DN150 PN16 Form C EN 1092 1 Form B1 D2 Flange DIN DN150 PN40 Form C EN 1092 1 Form B1 A1 Flange ANSI 6 150 RF SF A2 Flange ANSI 6 300 RF SF A3 Flange ANSI 3 600 RF SF Others on request RHM 80 Basic Order Code RHM 80 General Specifications RHM 80 Temperature Range NT Models from 20 to 120 C 4 to 248 F ET Models from 45 to 120 C 49 to 248 F ET2 Models from 45 to 210 C 49 to 410 F ET1 Models f...

Отзывы: