Performance RHM 40
Max Flow Rate Qmax = 1500 kg/min (3307 lb/min) and Qnom (*) = 1250 kg/min (2756 lb/min)
Standard Models
Flow Rate
Uncertainty
kg/min
lb/min
in % of reading
1500
3307
0.20
1200
2646
0.20
600
1323
0.20
60
132
0.20
30
66
0.50
Uncertainty % DP (bar)
Flow Rate kg/min
Goldline Models (**) - selected sensors
Flow Rate
Uncertainty
kg/min
lb/min
in % of reading
1000
2205
0.15
600
1323
0.15
400
882
0.15
200
441
0.15
100
220
0.15
Low Flow Models (**) - selected sensors
Flow Rate
Uncertainty
kg/min
lb/min
in % of reading
1200
2646
0.20
600
1323
0.20
60
132
0.20
30
66
0.50
25
55
0.60
Uncertainty % DP (bar)
Flow Rate kg/min
(**) Selected sensors are only available in combination
with temperature options T1, TA, standard material and
pressure range.
• Serial/single path versions offer the same accuracy at
half the flow (Qmax serial version = 750 kg/min).
• Uncertainty of reading (incl. zero drift) indications refer
to reference conditions H2O, 18-24°C (66 - 76°F), 1 - 3
bar (15 – 45 psi) and installation according to field
manual.
• Pressure drop indications refer to H
2
O, with parallel
measuring loops type P1.
• For calibration to customer range and / or with
improved uncertainty, please consult your local
agent.
Uncertainty % DP (bar)
Repeatability
Better ± 0.1% of rate,
Goldline 0.05%
Density
Down to 0.5% uncertainty
Temperature
Better ± 1°C
(*) Nominal flow Qnom refers to roughly 8 - 10 m/s
(26 - 33 ft/s) velocity in measuring loops for best
performance.