LP CONVERSION

The LP orifi ces are located in a small pack on the 
back of the oven next to the gas regulator. Use a  

1

/

2

-in. open end wrench to install the orifi ces. Turn 

the orifi ce clockwise until snug. 

OVEN CAPILLARY

The oven capillary is held in by 2 clips. To remove 
the capillary, squeeze both clips at the same time  
and gently pull the capillary away from the oven 
wall.

OVEN DOOR GASKET

The oven door gasket is  held in place by spring 
clips. To remove it, place a fi nger under the gasket 
beside each clip and gently pull straight out. 

BROILER DOOR REMOVAL

Open the broiler door and insert a pin into each 
door hinge as shown. Remove the 2 Phillips head 
screws from each hinge. Slide the drawer off the 
hinges.

Capillary

Clip

Screws

Pin 