Installation Instructions

Install the Internal Drain

Location of the Drain in the Cabinet Bottom

1.  The Drain Kit must be installed on the bottom of 

the wall sleeve prior to installation of the sleeve in 
the wall. The location should not be in the area of 
chassis supports or molded ribs (molded sleeve 
only). 

NOTE: 

If

 

installation in the wall requires the use of a 

sub-base, the location of the drain should be at least 
3” from the front edge of the wall sleeve. 

2.  After location of Drain Kit is determined, locate and 

drill 3 holes per dimensions on Fig. 3. The steel 
mounting plate with the 1/2” center hole can also be 
used as a template to mark holes. Repaint edges 
of drilled holes on metal cabinet to prevent rust or 
corrosion. 

11/16”

1-3/8”

1/2” Diameter

3/32”

5/32” Diameter
(2 holes)

3.  The gasket should be placed on the steel mounting 

plate (with 1/2” hole) with screw holes in gasket 
lined up with screw holes in steel mounting plate. 
Then insert drain tube through gasket and steel 
mounting plate, as shown in Fig. 4. 

Nuts

Gasket

Sleeve bottom

Tube

” O.D.

Steel mounting plate

Pan Head screws

 

Fig. 4

 

Screw “A” 

for metal 

sleeves

Screw “B” 

for molded 

sleeves

Install the Internal Drain (cont.)

4.  Attach this assembly to bottom of the wall sleeve 

with two Type A screws through the cover plate, 
gasket, and wall sleeve. On molded sleeve, the 2 
speed nuts must be used to secure drain kit wall 
sleeve using the two Type A screws. 

5.  Seal external drain holes. Prepare the remaining 

mounting plates/gasket assemblies as shown in Fig. 
2. Using the screws (Type A for Steel or Type B for 
Molded sleeve) attach plate/gasket assemblies to 
the bottom exterior flange over both as shown.

6.  Install the wall sleeve into the wall opening (level in 

all directions) and secure with adequate fasteners 
per instructions packed with the wall sleeve. 

7.  A tube or hose 1/2” I.D. (obtained locally) must be 

installed on the drain and connected to the internal 
drain system in the building. 

Fig. 3