Installation Instructions

1 Ft = 0.3 m

1” = 2.5 cm

8

TOOLS AND MATERIALS REQUIRED

(NOT SUPPLIED)

Duct Tape

¼” Pivoting Hex Socket

Pencil and

Tape Measure

Spirit Level

Phillips and

Flat Blade Screwdrivers

Electric Drill with

1/8” and 3/8” Bits

cUL Listed Wire Nuts

Hammer

Safety Glasses

Metal Snips

Flashlight

Pliers

Wire Cutter/Stripper

Saber Saw or Key Hole Saw

Ladder

Allen Wrench

• 4 #10 pan head wood screws for installation on the

bottom of a cabinet.

CAUTION!

Lamps are not supplied; use ONLY

120 Volt, 50 Watt (maximum) 50° halogen light made for
a GU10 base, suitable for use in open luminaries.

Additional Materials:

• 120V 60Hz. 15 or 20 Amp, 2-wire with ground,

properly grounded branch circuit.

• Strain relief for junction box.
• ½” conduit.
• Round or rectangular duct.
• Round backdraft damper.

PARTS PROVIDED

• Hood canopy assembly with blower already installed
• Grease filters
• Drip trays
• Care & Use/Installation Instructions
• Fittings bag with:

2 Drip trays holding br plastic washers and knobs
4 Washers
6 Drywall anchors
2 Hooks with regulating screws
6 Screws 5 x 35
4 Screws 4 x 8 for transition
1 Transition

INSTALLING THE HOOD

• For the most efficient air flow exhaust, use a straight

run or as few elbows as possible.

CAUTION!

Vent unit to outside of building only.

• One person is necessary for installation.

On average 2 hours are necessary to complete
installation (not including cut to be made in wall
and/or cabinet, installation of ducts, conduit and
electrical connections to the mains).

Installation steps:

12 installation steps are required for both installation
methods: wall mount or in alternative cabinet installation
• The hood is fitted with screws and drywall anchors

suitable for most surfaces. Consult a qualified installer
to check if they perfectly fit with your cabinet/wall.

• Do not use flex ducting.
• COLD WEATHER installations should have an

additional backdraft damper installed to minimize
backward cold air flow and a non metallic thermal
break to minimize conduction of outside temperatures
as part of the ductwork. The damper should be on the
cold air side of the thermal break.
The break should be as close as possible to where the
ducting enters the heated portion of the house.

• Make up air: local building codes may require the use of

make-Up air systems when using ducted ventilation
systems greater than specified CFM of air movement. The
specified CFM varies from locale to locale. Consult your
HVAC professional for specific requirements in your area.

OPTIONAL ACCESSORIES

Ductless Recirculation Kit:

• KITRIALTO 30”: PVUS830
• KITRIALTO 36”: PVUS836

Содержание PVUS830

Страница 1: ...faces 5 Stainless Steel Surfaces 5 Installation Instructions 7 13 Troubleshooting Tips 16 Consumer Support Consumer Support Back Cover Product Registration 17 18 Warranty 19 Write the model and serial numbers here Model ________________ Serial ________________ You can find them on a label on the inside of the hood PVUS830 PVUS836 Owner s Manual and Installation Instructions www GEAppliances ca ...

Страница 2: ...ON To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING A SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO ...

Страница 3: ...th all applicable codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for He...

Страница 4: ...t when the only air currents are those created by the blower itself For Gas Cooktops a lower blower speed should be used if the gas flame is being distorted by the air movement the burner continually sparks clicks the burner flame repeatedly blows out CAUTION Lamps are not supplied use ONLY 120 Volt 50 Watt maximum 50 halogen light made for a GU10 base suitable for use in open luminaries Consumer ...

Страница 5: ...es 2 3 Place and seat the drip tray into the hood track Slide trays left or right until all trays are side by side in place in the track Firmly secure the drip trays with the the drip tray holding brackets Filters and Drip Trays To clean the hood surface use a hot damp cloth with a mild detergent suitable for painted surfaces Use a clean hot damp cloth to remove soap Dry with a dry clean cloth Do ...

Страница 6: ...cuit breaker panel Be sure to let the light cover and bulb cool completely For your safety do not touch a hot bulb with bare hands or a damp cloth To remove Using gloves or a dry cloth remove the bulb by twisting counterclockwise To replace Use a new 120 volt 50 watt maximum 50 halogen light made for a GU10 base suitable for use in open luminaries Using gloves or a dry cloth remove the new bulb fr...

Страница 7: ...locked securely fasten a prominent warning device such as a tag to the service panel FOR YOUR SAFETY WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction B Sufficient air is needed for proper com...

Страница 8: ... or as few elbows as possible CAUTION Vent unit to outside of building only One person is necessary for installation On average 2 hours are necessary to complete installation not including cut to be made in wall and or cabinet installation of ducts conduit and electrical connections to the mains Installation steps 12 installation steps are required for both installation methods wall mount or in al...

Страница 9: ...n Ducting Provide a round duct having a diameter of 8 See Fig 2 and Fig 3 on page 11 for location on cabinet bottom Install a conduit from the service panel long enough to reach the hood once it is installed Power supply must be rated for 120 V AC 60 Hz 15 or 20 A INSTALLING THE HOOD Continued Installation Instructions 9 EXAMPLES OF POSSIBLE DUCTING Lamp Charcoal filters Deflector 24 to 30 Recircu...

Страница 10: ...ENT LENGTH QTY USED EQUIVALENT LENGTH SIZE ROUND STRAIGHT 3 x 10 STRAIGHT 3 x 14 STRAIGHT 90 ELBOW ROUND 45 ELBOW ROUND 3 x 10 90 ELBOW 3 x 10 45 ELBOW 3 x 10 FLAT ELBOW ROUND TO 3 x 10 3 x 10 TO ROUND ROUND TO 3 x 10 90 ELBOW 3 x 10 TO ROUND 90 ELBOW 3 x 10 CENTER REVERSE ELBOW LEFT 3 x 10 CENTER REVERSE ELBOW RIGHT 3 x 10 RIGHT REVERSE ELBOW 3 x 10 LEFT REVERSE ELBOW ROUND WALL CAP Model WC8 Mod...

Страница 11: ...needed 12 2 10 4 15 16 1 7 8 2 6 Rear Wall 1 Dia Holes Vertical Conduit Option Bottom of Cabinet or Soffit Vertical Discharge Figure 1 Cabinet Front CL Hood Width 12 Ø 8 7 16 1 7 8 2 7 16 8 13 16 Cabinet Front Figure 2 Rear Wall 1 Dia Holes Vertical Conduit Option Bottom of Cabinet or Soffit Horizontal Discharge CL Hood Width 12 11 3 9 16 23 1 16 Figure 3 2 Discharge Direction The hood is shipped ...

Страница 12: ...red hood installation height plus 7 See also Fig 6a 5 Find the centerline of the cooktop Draw a vertical line along this centerline up to the horizontal line drawn in step 1 and draw a vertical line right and left at a distance of 12 5 8 to determine the mounting location of the mounting hooks shipped with the hood 6 Fit two mounting hooks on the wall to hang the hood through the provided slots 2 ...

Страница 13: ...f the Hood Screw for Cabinet Bottom Installation CL Figure 6b CL Adjusting Screw 11 Wiring the hood WARNING Electrical Shock Hazard Turn off power at the service panel before wiring this unit 120 VAC 15 or 20 Amp circuit required ELECTRICAL GROUNDING INSTRUCTIONS THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES ONE OF WHICH GREEN YELLOW SERVES TO GROUND THE APPLIANCE TO PROTEC...

Страница 14: ...14 Notes Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Care and Cleaning ...

Страница 15: ...15 Notes www GEAppliances ca Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Care and Cleaning ...

Страница 16: ... connector is loose Disconnect power to the unit Remove the filters or not plugged into its mating and look up at the blower If the blower connector connector plug is loose or you see the connector dangling the installer failed to plug it in securely Although it is a blind connection it is easy to plug in See the Installation Instructions in this manual for the plug location and how to plug the co...

Страница 17: ...ERSHIP REGISTRATION P O BOX 1780 MISSISSAUGA ONTARIO L4Y 4G1 FOR CANADIAN CONSUMERS ONLY POUR RÉSIDENTS CANADIENS SEULEMENT Please place in envelope and mail to Veuillez mettre dans une enveloppe et envoyez à ...

Страница 18: ...NO NO RUE STREET NAME RUE APT NO APP RR CITY VILLE PROVINCE AREA CODE IND RÉG TELEPHONE TÉLÉPHONE E MAIL COURRIEL DID YOU PURCHASE A SERVICE CONTRACT FOR THIS APPLIANCE AVEZ VOUS ACHETÉ UN CONTRAT DE SERVICE POUR CET APPAREIL YES OUI NO NON IF YES SI OUI EXPIRATION Y A M D J NAME OF SELLING DEALER NOM DU MARCHAND INSTALLATIONDATE DATED INSTALLATION Y A M D J CORRESPONDENCE ENGLISH CORRESPONDANCE F...

Страница 19: ...aple your receipt here Proof of the original purchase date is needed to obtain service under the warranty Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Care and Cleaning 19 This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within Canada If the product is located in an area where service by a Mabe Auth...

Страница 20: ...ca Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Order on line today 24 hours every day or by phone at 1 800 661 1616 during normal business hours Instructions contained in this manual cover procedures to be performed by any user Other servicing generally should be referred to qualifi...

Отзывы: