Installation Preparation

PREPARING FOR INSTALLATION

• Unpack the cooktop and read the Installation 

Instructions to understand the required countertop 

cutout dimensions and location in the countertop, 

the cooktop spacing to the front edge of the 

countertop, and the required clearances to the 

cabinets and walls. The vent system required cutout 

ZLGWKLVVKRZQRQSDJH&RQ¿UPWKHUHLVHQRXJK

side to side counter space to meet the required 

spacing and clearances for the cooktop.

• Using the illustrations below and taking 

measurements of the cooktop to establish 

GLPHQVLRQ$FRQ¿UPWKHUHLVHQRXJKIURQWWREDFN
FRXQWHUVSDFHGLPHQVLRQ%WR¿WERWKWKHFRRNWRS

and the vent system. Note the cooktop rear edge 

ZLOORYHUODSWKHYHQWV\VWHPIURQWVXUIDFHUHIHUWR
3DJH

• Refer to the Creative Solutions section on page 8 if 

more counter space is needed.

• Using the illustrations on pages 5 through 7 and 

taking measurements of the vent system and its 

H[KDXVWYHQWORFDWLRQFRQ¿UPWKHFOHDUDQFHV

needed within the cabinet, the exhaust vent 

direction, and the alignment of the exhaust vent with 

the ducting. If needed for clearance or duct hookup 

alignment, reposition the location of the cooktop, 

or modify the cabinetry, or modify the ducting. A 

remote blower kit JXR867 is available to move the 

blower assembly out of the cabinet area.

‡&RQ¿UPWKHHOHFWULFDOUHFHSWDFOHVDQGJDVOLQHVDUH

correctly located, and relocate if needed.

Side View: Installed Vent

Front View: Installed Vent

Cooktop

Cooktop

4-1/2” Max

5-1/2”
Max

5-1/2”

Max

B

C

B is the minimum dimension of the

flat portion of countertop that is needed

A

A is the dimension from the screw head on the front surface of

the cooktop base to the rear edge of the cooktop, dimension A can also be

located in cooktop Installation Instructions.

Depth of cutout is A + 2 1/8”

Minimum counter depth B = A + C + 2.5"

Dimension C is defined in cooktop Installation Instruction

COOKTOP

1/8” minimum

Front edge

of countertop

Front of cutout

in countertop

Screw head

Front

edge

of

cooktop

Front of cutout
in countertop

Back edge

of cooktop

Back of cut
in countertopout 

2 1/8”

3/8”
minimum

D

o

w

n
d

r

a

f
t

V
e
n

t

Содержание PVB94

Страница 1: ...1 Installation Instructions Downdraft Vent Systems PVB94 PVB98 ZVB30 ZVB36 31 10728 8 11 14 GE...

Страница 2: ...stalled and grounded WARNING Improper grounding can result in a risk of electric shock Consult a qualified electrician if the grounding instructions are not completely understood or if doubt exist as...

Страница 3: ...WKH PHULFDQ 6RFLHW for Heating Refrigeration and Air Conditioning QJLQHHUV 6 5 DQG WKH ORFDO FRGH DXWKRULWLHV When cutting or drilling into wall or ceiling do not damage electrical wiring and other h...

Страница 4: ...and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse A properly grounded 3 prong receptacle should be located within reach...

Страница 5: ...Optional accessory for indoor remote location of the blower motor assembly Use this kit when the blower and motor assembly will be located RXWVLGH RI WKH FDELQHW VXFK DV EHORZ WKH FDELQHW RRU 9 3 45...

Страница 6: ...UP WKH FOHDUDQFHV needed within the cabinet the exhaust vent direction and the alignment of the exhaust vent with the ducting If needed for clearance or duct hookup alignment reposition the location...

Страница 7: ...o the countertop opening To change to a left or right discharge Remove the 4 screws holding the blower and the mounting plate assembly to the downdraft vent Retain screws Remove blower assembly turn i...

Страница 8: ...ides The front of the opening must clear the front support rail on the cabinet and the rear of the opening must clear the rear support of the cabinet Chamfer all exposed edges of decorative laminate t...

Страница 9: ...t arrangement under concrete slab PVC duct should be used if installing under a poured concrete slab PREPARE FOR DUCTWORK Determine the best route for ductwork it can be routed in a variety of ways de...

Страница 10: ...LV sitting on top of the countertop C Secure the screws for the stabilizing brackets to the cabinet back and side walls D RQ UP WKH YHQW V VWHP LV SOXPE DQG VTXDUH with the cabinetry Installation Ins...

Страница 11: ...nt the remote switch on the countertop such that the switch connectors stay located in the 1 2 dia hole Stick adhesive wire clamp near the 1 2 dia hole and attach the loose wire with a wire tie WARNIN...

Страница 12: ...Adjust the blower by pressing HIGHER or LOWER To lower the vent press the ON OFF pad NOTE It is not necessary to turn the fan OFF before lowering the vent The fan will automatically WXUQ R ZKHQ WKH YH...

Отзывы: