12
Installation Instructions
3 INSTAll coNTRol SWITch
(on some models)
Skip this step if there is no separate control switch.
connect Wire lead to control box
• Connect the mating wire ends.
• Place the adhesive wire clamps (provided) near
the mating connector.
• Keep approximately 3"-long wire and attach
the wire to the clamp with a wire tie. This will act
as a strain relief.
• Drill a 1/2"-dia. hole into the desired location.
Use the mounting bracket as a template to locate
the hole accurately. Check for interference
between the switch cover, adjacent objects
and cooktop/vent overlaps.
• If switch is mounted into a tile surface, drill the hole
between tiles. Use locally approved caulking to
cover any gaps.
connect control Switch to Remote harness
• Thread the remote harness through the 1/2"-dia.
hole and attach the harness connector to the
remote connector.
• Remove the paper backing on the foam piece
and mount the remote trim on the countertop
such that the switch connectors stay located
in the 1/2"-dia. hole.
• Stick adhesive wire clamp near the 1/2"-dia. hole
and attach the loose wire with a wire tie.
WARNING:
Disconnect electrical power from unit before
beginning switch installation. Failure to do so could
result in personal injury or damage to the electrical
controls.
Determine the location for the control switch.
The wiring lead is 68" long.
Control
Box
1/2"-Dia.
Hole
Foam Piece With Adhesive
Mounting Surface
Remote Switch
Strain Relief
(Adhesive wire clamp
with tie)
Remote Harness
Remote Harness
Mating Connectors
Strain Relief
(Adhesive wire clamp
with tie)
Содержание PVB37